Please make sure that there are no obvious transport damages. Should you notice any damages on the A/C 
connection cable or on the casing, do not take the device into operation and immediately consult your local 
dealer. 
 
This  device  falls  under  protection-class  I.  The  power  plug  must  only  be  plugged  into  a  protection  class  I 
outlet.  The  voltage  and  frequency  must  exactly  be  the  same  as  stated  on  the  device.  Wrong  voltages  or 
power outlets can lead to the destruction of the device and to mortal electrical shock. 
 
Always  plug  in  the  power  supply  plug  least.  The  power  plug  must  always  be  inserted  without  force.  Make 
sure that the plug is tightly connected with the outlet. 
 
Never  let  the  power-cord  come  into  contact  with  other  cables!  Handle  the  power-cord  and  all  connections 
with  the  mains  with  particular  caution!  Never  touch  them  with  wet  hands,  as  this  could  lead  to  mortal 
electrical shock. 
 
Never modify, bend, strain mechanically, put pressure on, pull or heat up the power cord. Never operate next 
to sources of heat or cold. Disregard can lead to power cord damages, fire or mortal electrical shock. 
 
The  cable  insert  or  the  female  part  in  the  device  must  never  be  strained.  There  must  always  be  sufficient 
cable to the device. Otherwise, the cable may be damaged which may lead to mortal damage. 
 
Make  sure  that  the  power-cord  is  never  crimped  or  damaged  by  sharp  edges.  Check  the  device  and  the 
power-cord from time to time. 
 
If  extension  cords  are  used,  make  sure  that  the  core  diameter  is  sufficient  for  the  required  power 
consumption  of  the  device.  All  warnings  concerning  the  power  cords  are  also  valid  for  possible  extension 
cords. 
 
Always  disconnect  from  the  mains,  when  the  device  is  not  in  use  or  before  cleaning  it.  Only  handle  the 
power-cord by the plug. Never pull out the plug by tugging the power-cord. Otherwise, the cable or plug can 
be damaged leading to mortal electrical shock. If the power plug  or the power switch is not accessible, the 
device must be disconnected via the mains. 
 
If the power plug or the device is dusty, the device must be taken out of operation, disconnected and then be 
cleaned  with  a  dry  cloth.  Dust  can  reduce  the  insulation  which  may  lead  to  mortal  electrical  shock.  More 
severe dirt in and at the device should only be removed by a specialist. 
 
There  must  never  enter  any  liquid  into  power  outlets,  extension  cords  or  any  holes  in  the  housing  of  the 
device. If you suppose that also a minimal amount of liquid may have entered the device, it must immediately 
be  disconnected.  This  is  also  valid,  if  the  device  was  exposed  to  high  humidity.  Also  if  the  device  is  still 
running,  the  device  must  be  checked  by  a  specialist  if  the  liquid  has  reduced  any  insulation.  Reduced 
insulation can cause mortal electrical shock. 
 
There must never be any objects entering into the device. This is especially valid for metal parts. If any metal 
parts like staples or coarse metal chips enter into the device, the device must be taken out of operation and 
disconnected immediately. Malfunction or short-circuits caused by metal parts may cause mortal injuries. 
 
The total weight of the installation (=total weight of all individual parts) must never exceed the maximum load 
of the installation area. 
 
If the power distributor will be installed on a trussing system or be suspended, it must always be secured with 
an appropriate safety-rope! 
 
Keep away children and amateurs! 
 
Never leave this device running unattended. 
 
 

Summary of Contents for SAB-322

Page 1: ...Copyright Nachdruck verboten Reproduction prohibited F r weiteren Gebrauch aufbewahren Keep this manual for future needs BEDIENUNGSANLEITUNG USER MANUAL SAB 322 Power Split Box...

Page 2: ...ION 10 2 SAFETY INSTRUCTIONS 10 3 OPERATING DETERMINATIONS 12 4 DESCRIPTION 13 5 INSTALLATION 13 6 CLEANING AND MAINTENANCE 15 7 TECHNICAL SPECIFICATIONS 16 Diese Bedienungsanleitung gilt f r die Arti...

Page 3: ...Hinweise beachten sind wir sicher dass Sie lange Zeit Freude an Ihrem Kauf haben werden Nehmen Sie den SAB 322 aus der Verpackung 2 SICHERHEITSHINWEISE ACHTUNG Seien Sie besonders vorsichtig beim Umg...

Page 4: ...n Ger t bei Nichtbenutzung und vor jeder Reinigung vom Netz trennen Fassen Sie dazu den Netzstecker an der Griffl che an und ziehen Sie niemals an der Netzleitung Ansonsten kann das Kabel und der Stec...

Page 5: ...lage zwischen 20 und 2000 m ber NN betrieben werden Der Umgebungsverschmutzungsgrad darf 1 nicht berschreiten keine oder nur trockene nichtleitende Verschmutzung Verwenden Sie das Ger t nicht bei Gewi...

Page 6: ...en sein dass sie 1 Stunde lang ohne dauernde sch dliche Deformierung das 10 fache der Nutzlast aushalten kann Die Installation muss immer mit einer zweiten unabh ngigen Aufh ngung z B einem geeigneten...

Page 7: ...und oder zur Besch digung von Eigentum f hren Die Installation muss au erhalb des Handbereichs von Personen angebracht werden 5 1 Montage an einer Traverse Achtung Traverseninstallationen k nnen beim...

Page 8: ...technische Einrichtungen mindestens einmal j hrlich durch einen Sachkundigen gepr ft werden Dabei muss unter anderem auf folgende Punkte besonders geachtet werden 1 Alle Schrauben mit denen das Ger t...

Page 9: ...en Ma nahmen zu pr fen Die Verantwortung f r die ordnungsgem e Durchf hrung der Pr fungen obliegt einer Elektrofachkraft Ortsver nderliche elektrische Betriebsmittel Verl ngerungs und Ger teanschlussl...

Page 10: ...ructions given in this manual we are sure that you will enjoy this device for a long period of time Unpack your SAB 322 2 SAFETY INSTRUCTIONS CAUTION Be careful with your operations With a dangerous v...

Page 11: ...o valid for possible extension cords Always disconnect from the mains when the device is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the...

Page 12: ...operated in an altitude between 20 and 2000 m over NN The ambient contamination must never exceed level 1 and must not be conducting only dry Never use the device during thunderstorms Over voltage cou...

Page 13: ...ucted in a way that it can hold 10 times the weight for 1 hour without any harming deformation The installation must always be secured with a secondary safety attachment e g an appropriate catch net T...

Page 14: ...allation on a trussing system Caution Trussing installations may cause severe injuries when crashing down If you have doubts concerning the safety of a possible installation do NOT install the trussin...

Page 15: ...ere must not be any deformations on housings fixations and installation spots ceiling suspension trussing 3 The electric power supply cables must not show any damages material fatigue e g porous cable...

Page 16: ...Should you have further questions please contact your dealer 7 TECHNICAL SPECIFICATIONS Power supply 380 V AC 50 Hz Max power 22080 W Max power channel 11040 W Max current channel 32 A Dimensions LxW...

Reviews: