background image

12

The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
This secondary safety attachment must be constructed in a way that no part of the installation can fall down if
the main attachment fails.

When rigging, derigging or servicing the fixture staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.

The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert before taking into operation for the first time and after changes before taking into operation another
time.

The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert after every four year in the course of an acceptance test.

The operator has to make sure that safety-relating and machine-technical installations are approved by a
skilled person once a year.

Procedure:

The projector should be installed outside areas where persons may walk by or be seated.

IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not limited to)
calculating working load limits, installation material being used, and periodic safety inspection of all
installation material and the projector. If you lack these qualifications, do not attempt the installation yourself,
but instead use a professional structural rigger. Improper installation can result in bodily injury and.or damage
to property.

The projector has to be installed out of the reach of people.

If the projector shall be lowered from the ceiling or high joists, professional trussing systems have to be used.
The projector must never be fixed swinging freely in the room.

Caution:

 Projectors may cause severe injuries when crashing down! If you have doubts concerning the

safety of a possible installation, do NOT install the projector!

Before rigging make sure that the installation area can hold a minimum point load of 10 times the projector's
weight.

DANGER OF FIRE!

When installing the device, make sure there is no highly-inflammable

material (decoration articles, etc.) within a distance of min. 0.5 m.

Mount the projector with the mounting-bracket to your trussing system using an appropriate clamp. The hole
in the mounting bracket has a diameter of 10 mm.

For overhead use, always install a safety-rope that can hold at least 10 times the weight of the fixture. You
must only use safety-ropes with screw-on carabines. Pull the safety-rope through the hole in the mounting-
bracket and over the trussing system etc. Insert the end in the carabine and tighten the fixation screw.

Adjust the desired inclination-angle via the mounting-bracket and fix the bracket-screws tightly.

Connect the fixture to the mains with the power-plug.

The occupation of the connection-cables is as follows:

Cable

Pin

International

Brown

Live

L

Blue

Neutral

N

Yellow/Green

Earth

The earth has to be connected!

Summary of Contents for MF-5

Page 1: ...ng effect F r weiteren Gebrauch aufbewahren Keep this manual for further needs Gardez ces instructions pour des utilisations ult rieurs Guarde este manual para posteriores usos COPYRIGHT Nachdruck ver...

Page 2: ...ler in Verbindung SICHERHEITSHINWEISE ACHTUNG Seien Sie besonders vorsichtig beim Umgang mit gef hrlicher Netzspannung Bei die ser Spannung k nnen Sie einen lebensgef hrlichen elektrischen Schlag erha...

Page 3: ...l st werden k nnen gilt besonders f r Epileptiker Beachten Sie bitte dass Sch den die durch manuelle Ver nderungen an diesem Ger t verursacht werden nicht unter den Garantieanspruch fallen Kinder und...

Page 4: ...en Die Lampe muss gewechselt werden wenn diese besch digt ist oder sich durch W rme verformt hat ACHTUNG Vor dem Wechseln der Lampe diese unbedingt erst abk hlen lassen ca 5 Minuten und das Ger t allp...

Page 5: ...hkundigen gepr ft werden Vorgehensweise Der Projektor sollte idealerweise au erhalb des Aufenthaltsbereiches von Personen installiert werden WICHTIG BERKOPFMONTAGE ERFORDERT EIN HOHES MA AN ERFAHRUNG...

Page 6: ...Schalter mit folgenden Funktionen 0 Lampe aus I Lampe permanent an musikgesteuerte Strahlenbewegung II Musikgesteuerte Lampenschaltung musikgesteuerte Strahlenbewegung REINIGUNG UND WARTUNG Der Unter...

Page 7: ...n Vor dem Sicherungswechsel ist das Ger t allpolig von der Netzspannung zu trennen Netzstecker ziehen Vorgehensweise Schritt 1 Drehen Sie den Sicherungshalter an der Ger ter ckseite mit einem passende...

Page 8: ...Ma e LxBxH 280 x 220 x 160 mm Gewicht 3 kg Passende Lampe 230 V 300 W G 6 35 Maximale Umgebungstemperatur ta 45 C Maximale Leuchtentemperatur im Beharrungszustand tB 90 C Passende Sicherung F 2 A 250...

Page 9: ...ice SAFETY INSTRUCTIONS CAUTION Be careful with your operations With a dangerous voltage you can suffer a dangerous electric shock when touching the wires This device has left our premises in absolute...

Page 10: ...to be operated with an alternating voltage of 230 V 50 Hz and was designed for indoor use only This device is designed for professional use e g on stages in discotheques theatres etc Lighting effects...

Page 11: ...s with a higher wattage generate temperatures the device was not designed for Damages caused by non observance are not subject to warranty For installation a 230 V 300 W G 6 35 lamp is required The la...

Page 12: ...ead use a professional structural rigger Improper installation can result in bodily injury and or damage to property The projector has to be installed out of the reach of people If the projector shall...

Page 13: ...he device have to be tighly connected and must not be corroded 2 There must not be any deformations on housings fixations and installation spots ceiling suspension trussing 3 Mechanically moved parts...

Page 14: ...ll be damaged cable firmly connected with the device it has to be replaced by authorized dealers only in order to avoid hazards If the power supply cable of this device will be damaged replaceable cab...

Page 15: ...nsport Si tel tait le cas contactez imm diatement votre revendeur INSTRUCTIONS DE S CURIT ATTENTION Soyez prudent lors de manipulations lectriques avec une tension dangereuse vous tes soumis des risqu...

Page 16: ...eux pour creer des effets d coratifs Cet appareil doit seulement tre connect avec une tension alternative de 230 V 50 Hz et a t con u pour un usage dans des locaux clos Cet appareil est pr vu pour des...

Page 17: ...ce sup rieure la temp rature d gag e par celles ci tant trop haute pour cet appareil En cas de non respect de cette consigne la garantie n est plus valable Pour l installation vous avez besoin d une l...

Page 18: ...N essayez jamais proc der une installation vous m me si vous ne disposez pas d une telle qualification mais en commissionnez un installateur professionnel Des installations incorrectes peuvent causer...

Page 19: ...re autres il faut respecter particuli rement les points suivants 1 Tous les vis avec lesquelles l appareils ou des parties de l appareil sont mont s doivent tre fix ment serr es et ne doivent pas tre...

Page 20: ...s utiliser des pi ces d origine Quand le c ble d alimentation de cet appareil soit endommag c ble fix l appareil il doit tre remplac par un installateur agr e pour viter des dangers Quand le c ble d a...

Page 21: ...transporte Si los hubiese consulte a su proveedor y no use el aparato INSTRUCCIONES DE SEGURIDAD Tenga cuidado cuando opere con este aparato Con un voltaje peligroso puede sufrir una peligrosa descar...

Page 22: ...galo lejos del alcance de los ni os y de personal no profesional INSTRUCCIONES DE MANEJO Este aparato es un efecto luminoso para crear efectos de decoraci n El aparato s lo es permitido para una conex...

Page 23: ...desenchufe lo de la corriente y deje que la l mpara se enfrie Durante la instalaci n no toque las bombillas de cristal con las manos sin protecci n Por favor siga las indicaciones del fabricante de l...

Page 24: ...ocedimiento El proyector debe ser instalado fuera de reas d nde personas pueden entretenerse IMPORTANTE UNA MONTAJE POR ENCIMA DE LA CABEZA REQUIERA MUCHA EXPERIENCIA sto incluye pero no es limitadoa...

Page 25: ...seguridad y de m quinas son inspeccionados por un perito en la extension de una inspecci n inicial cada cuatro a os por lo menos El empresario debe asegurar que instalaciones de seguridad y de m quina...

Page 26: ...aso 2 Sacar el fusible viejo del portafusibles Paso 3 Instalar el fusible nuevo en el portafusibles Paso 4 Volver a colocar el portafusibles en la caja y atornillarlo En caso de que necesite piezas de...

Reviews: