Disconnect from mains before starting maintenance operation!
DANGER TO LIFE!
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
There are no serviceable parts inside the device. Maintenance and service operations are only to be carried
out by authorized dealers.
Replacing the fuse
If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1:
Open the fuseholder on the rearpanel with a fitting screwdriver.
Step 2:
Remove the old fuse from the fuseholder.
Step 3:
Install the new fuse in the fuseholder.
Step 4:
Replace the fuseholder in the housing.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by a special power supply
cable available at your dealer.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
WMB-830
WMB-880
Power supply:
230 V AC, 50 Hz ~
230 V AC, 50 Hz ~
Power consumption:
45 W
70 W
Sound-control:
via built-in microphone
via built-in microphone
Dimensions (LxWxH):
925 x 145 x 220 mm
1305 x 150 x 220 mm
Weight:
6 kg
9 kg
Fuse:
F 1 A, 250 V
F 1 A, 250 V
Please note: Every information is subject to change without prior notice. 17.01.2006 ©