background image

00041772.DOC, Version 1.2

8/10

Please make sure that there are no obvious transport damages. Should you notice any damages on the
connection cable or on the casing, do not take the device into operation and immediately consult your local
dealer.

DANGER TO LIFE!

The electric connection must only be carried out by a qualified electrician!

This device falls under protection-class III. The device always has to be operated with an appropriate
transformer.

The installer must always make sure to connect suitable terminals, connectors and cables!

All valid instructions concerning the electric installation be adhered!

Keep away children and amateurs!

OPERATING DETERMINATIONS

This device is a luminaire for fixed installations. This product is only allowed to be operated with the voltage
given on the type plate.

This product was designed for indoor use only. The device must never be installed in damp rooms.

The ambient temperature must always be between -5° C and +45° C. Keep away from direct insulation
(particularly in cars) and heaters.

The relative humidity must not exceed 50 % with an ambient temperature of 45° C.

This device must only be operated in an altitude between -20 and 2000 m over NN.

The device is only allowed for ceiling or wall installation, but must not be installed in the ground.

This luminaire must never be covered by insulation material, vapour foils or similar building material. Danger
of burning!

Never operate heat-emitting devices (e.g. heating system) next to the installed luminaire. Do not install the
luminaire in the neighbourhood of heat-emitting installations (e.g. heating tubes).

This recessed luminaire must never be installed at furniture.

The F-symbol means: this device can be installed on normal inflammable surfaces.

The symbol 

- - -m

determines the minimum distance from lighted objects. The minimum distance

between light-output and the illuminated surface must be more than the given value.

Do not shake the device. Avoid brute force when installing or operating the device.

When choosing the installation-spot, please make sure that the device is not exposed to extreme heat,
moisture or dust. There should not be any cables lying around. You endanger your own and the safety of
others!

This device must never be operated or stockpiled in sourroundings where splash water, rain, moisture or fog
may harm the device. Moisture or very high humidity can reduce the insulation and lead to mortal electrical
shocks.

Never use solvents or aggressive detergents in order to clean the device! Rather use a soft and damp cloth.

Summary of Contents for LED Ball Spot

Page 1: ...Copyright Nachdruck verboten Reproduction prohibited F r weiteren Gebrauch aufbewahren Keep this manual for future needs BEDIENUNGSANLEITUNG USER MANUAL LED Ball Spot 12V 3x1W LEDs...

Page 2: ...UCTION 7 SAFETY INSTRUCTIONS 7 OPERATING DETERMINATIONS 8 INSTALLATION 9 Attachment 9 Connection with the mains 10 CLEANING AND MAINTENANCE 10 TECHNICAL SPECIFICATIONS 10 Diese Bedienungsanleitung gil...

Page 3: ...wir sicher dass Sie lange Zeit Freude an Ihrem Kauf haben werden Nehmen Sie den LED Kugelspot aus der Verpackung SICHERHEITSHINWEISE ACHTUNG Seien Sie besonders vorsichtig beim Umgang mit gef hrliche...

Page 4: ...ungstemperatur von 45 C nicht berschreiten Dieses Ger t darf nur in einer H henlage zwischen 20 und 2000 m ber NN betrieben werden Das Ger t ist nur zur Decken oder Wandmontage zugelassen darf aber ni...

Page 5: ...tigt werden kann Mittels Wasserwaage muss berpr ft werden dass das Ger t absolut plan befestigt wurde Das Ger t muss au erhalb des Handbereichs von Personen installiert werden Die Festigkeit der Insta...

Page 6: ...Ger teinneren befinden sich keine zu wartenden Teile Wartungs und Servicearbeiten sind ausschlie lich dem autorisierten Fachhandel vorbehalten Sollten einmal Ersatzteile ben tigt werden verwenden Sie...

Page 7: ...al we are sure that you will enjoy this device for a long period of time Unpack your LED Ball Spot SAFETY INSTRUCTIONS CAUTION Be careful with your operations With a dangerous voltage you can suffer a...

Page 8: ...20 and 2000 m over NN The device is only allowed for ceiling or wall installation but must not be installed in the ground This luminaire must never be covered by insulation material vapour foils or si...

Page 9: ...utely planar by using a water level The device must be installed out of the reach of people The device must always be installed via all fixation holes Do only use appropriate screws and make sure that...

Page 10: ...vents There are no serviceable parts inside the device Maintenance and service operations are only to be carried out by authorized dealers Should you need any spare parts please use genuine parts Shou...

Reviews: