00064492.DOC, Version 1.0
11/12
installation material. If you lack these qualifications, do not attempt the installation yourself, but instead use a
professional structural rigger. Improper installation can result in bodily injury and.or damage to property.
The installation has to be attached out of the reach of people.
Make sure that the projectors' minimum distance from lighted objects (symbol
- - -m
) and the maximum
ambient temperature
t
a
are never exceeded at the installation spot.
Caution:
The loads have to be installed in a balanced way.
Install the luminaires on the fundamental part and do always install a safety-rope. You must only use safety
bonds complying with DIN 56927, quick links complying with DIN 56926, shackles complying with DIN EN
1677-1 and BGV C1 carbines. The safety bonds, quick links, shackles and the carbines must be sufficiently
dimensioned and used correctly in accordance with the latest industrial safety regulations (e. g. BGV C1,
BGI 810-3).
Please note:
for overhead rigging in public or industrial areas, a series of safety instructions have to be
followed that this manual can only give in part. The operator must therefore inform himself on the current
safety instructions and consider them.
The manufacturer cannot be made liable for damages caused by incorrect installations or insufficient safety
precautions!
Pull the safety-rope through the attachment eyelet and over the trussing system or a safe fixation spot. Insert
the end in the quick link and tighten the safety screw.
5.2 Installation at a trussing system
Caution:
Trussing installations may cause severe injuries when crashing down! If you have doubts
concerning the safety of a possible installation, do NOT install the trussing!
Before rigging make sure that the installation area can hold a minimum point load of 10 times the
installation's weight.
For suspending crossbeams, Alu-Bars, etc. always use a minimum of two hooks.
Attach the upper fixation of a C-hook to the crossbeam and tighten the fixation screw. Attach the T-bar to the
lower fixation of a C-hook and tighten the fixation screw.
At the suspended part, always install a safety-rope that can hold at least 12 times the weight of the
installation. You must only use safety-ropes with quick link with screw cap. Pull the safety-rope through the
attachment eyelet and over the trussing system or a safe fixation spot. Insert the end in the quick link and
tighten the safety screw.
The trussing system must always be earthed!
DANGER TO LIFE!
Before taking into operation for the first time, the installation has to be approved by an expert!
5.3 Connections
5.3.1 Connection with the mains
Connect the device to the mains with the powercon input.
5.3.2 Outputs
Output is via 4 safety sockets.
Connect your loads via the output-sockets. The maximum load per channel is 2300 W. Please note that the
maximum current must never be exceeded.