background image

Programmation Evidence pour Pierre ELEC  en Anglais

PSE1-000M004-GB

F.M:03/12-Rev  11/13 Modifications plusieurs écrans

p :  1/10

PROGRAMMING 

PROGRAMMING INSTRUCTIONS : Ref PSE1-000M004-GB

577, rue Célestin Hennion

59144 Gommegnies

Tel : (33) 03 27 28 18 18

Fax : (33) 03 27 49 80 41

http://www.eurofours.com

email:[email protected]

PRESENTATION OF THE CONTROL PANEL   -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -    p.2

Explanation of the symbols showing the condition of the oven -  -  -  -  -  -  -  -  -    p.3

ACCESS LEVEL -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -    p.4
ACCESS TO THE VARIOUS MENUS-  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -    p.5
USER MENU : ACCESS TO THE PARAMETERS   -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -    p.5

Adjustment of recipes  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -    p.6
Date and Time adjustments   -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -    p.8
Setting of control board parameters -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -    p.9

The company reserves the right to change specifications without notice - Copying forbidden

TOUCHSCREEN REGULATOR

Summary of Contents for Pierre ELEC

Page 1: ...49 80 41 http www eurofours com email infos eurofours com PRESENTATION OF THE CONTROL PANEL p 2 Explanation of the symbols showing the condition of the oven p 3 ACCESS LEVEL p 4 ACCESS TO THE VARIOUS...

Page 2: ...read the manual to familiarize yourself with the use of the appliance Regulator Name Regulator Start Stop Manufacturer menu Installer menu User menu Access to the parameters according to the authoriza...

Page 3: ...ecomes blue during the automatic steam injection programmed in the recipe and reverts to grey as soon as steam injection stops During cycle press to obtain steam Release to stop steam injection Level...

Page 4: ...rization 0 No single setting can be modified The only active keys are Control board starting up Regulator stop Baking starting Stop of the baking Selection of the recipes Authorization 1 The MODIFICAT...

Page 5: ...CESS TO THE VARIOUS MENUS USER MENU ACCESS TO THE PARAMETERS Manufacturer menu Restricted access for after sales service Installer menu Restricted access for after sales service User menu Menus secure...

Page 6: ...s Capture of the recipe name Baking duration Deck temperature Deck temperature Steam injection duration Exhaust vent opening duration Adjustment of recipes Farmho Validation The recipe name can be com...

Page 7: ...n duration Press the right boxes to adjust the baking duration the temperatures the steam injection duration and the delay for exhaust vent opening before the end of baking this last field appears onl...

Page 8: ...usieurs crans p 8 10 Date and Time adjustments Date Settings Date Hour Friday Hour Day Automatically calculated in function of the date Press the floppy disk icon to register After 3 to 5 seconds the...

Page 9: ...zzer Volume Language Delay before standby mn Delay before standby mn 0 The screen remains always light on 0 The value mentioned represent the number of minutes without any operation After this delay t...

Page 10: ...ent hood when baking The Hood runs permanently during baking function is not activated In that case an operating time of the hood at the beginning of baking and a delay for starting of the hood before...