21
Every time the motor is started, the machines electronics need a moment to run a systems check and
initiate the safety system. The GYRO-TEC safety feature only engages 3 seconds after the motor is
started.
It is very important to note that this functionality raises the safety level, but does not prevent the
operator from using the machine incorrectly.
The operator should always follow instructions described in this manual and take all necessary safety
precautions.
4.10 Temperature control
The TUBE.55-T is equipped with an all-time electronic temperature protection. If the temperature of
the motor unit runs up to 70 Degree Celsius the motor unit will stop. After a few minutes it can be
started again.
When it is possible to start the motor again, let the motor run idle at full speed for a couple of
minutes to let the motor cool down more in an efficient way.
4.11 Tool lubrication
IN HORIZONTAL APPLICATIONS
In order to use the lubrication system, the tank must be filled with a cutting fluid or oil
1.
Make sure the flow regulator is closed
2.
Unscrew the cap
3.
Fill the container with cutting fluid or oil
4.
Screw the cap back on
Adjust the fluid flow as required using the flow regulator;
Add more cutting fluid if the shavings (metal chips) become blue.
VERTICAL AND OVERHEAD APPLICATIONS
Dip the cutter in cutting paste or apply an appropriate spray.
WARNING: Do not use the lubrication system in vertical or overhead drilling applications.
Instead use Euroboor cutting paste
Make sure to use only suitable cutting oil or fluid. Euroboor offers a wide range of cutting lubricants
for all tool and material combinations. Proper cooling will help you create better and faster results,
and extend the lifetime of your tools.