3.1 Servo drives installation
3.1.1 Installation conditions
Environment
conditions
Equipment location In an indoor location, Prevent exposure from direct sunlight, Free from dust, tangy caustic
gases, flammable gases, steam or the salt-contented, etc.
Altitude
1000m or below
Atmospheric
pressure
86kPa~106kPa
Operating
temperature
-10
℃
~40
℃
Storage temperature -20
℃
~60
℃
Humidity
Below 90% (no water-bead coagulation)
Vibration Strength
Below 0.5G
(
4.9m/s
2
)
,10~60Hz (Discontinuous)
IP rating
IP20
Power system
TN system (Note)
Note: TN system: A power distribution system having one point directly earthed, the exposed conductive parts of
the installation being connected to that points by protective earth conductor.