EunSung CoolShaping Operator'S Manual Download Page 1

 Operator Manual

 

Summary of Contents for CoolShaping

Page 1: ...Operator Manual...

Page 2: ...cifications to improve performance reliability or manufacturability Information furnished by Eunsung Global is believed to be accurate and reliable However Eunsung Global assumes no responsibility for...

Page 3: ...2 2 General Precaution Caution 2 3 Burn Hazard 2 4 Electrical Hazard 2 5 Cleaning Induced Hazard 2 6 Operation Safety 2 7 Installation Hazard 2 8 Contraindication 7 7 7 8 8 8 9 9 10 11 4 Site Prepara...

Page 4: ...Mode 6 6 L Applicator Mode 6 7 R Applicator Mode 6 8 Applicator Operating Buttons 5 Installation 5 1 About the Installation 5 2 Connect the Applicator 5 3 Fill up the Water 5 4 Connect the Power Cable...

Page 5: ...CoolShaping 5 Contents 8 Treatment Guideline 42 9 About Warranty 47 10 Tech Specification 48 11 Customer Support 48...

Page 6: ...or adjustments or performance of procedures other than those specified herein may put the operator and or the patient at risk Therefore before attempting to use or operate the system personnel operati...

Page 7: ...has been applied Always try to minimize shock and vibration Keep the in out side of applicator clean pay particular attention to peltier electrodes vacuum hole Check the integrity of all components D...

Page 8: ...ipment must be connectedonly to an electrical supply outlet with protective earth Do not touch the applicator connector while the system is turned on this may cause electrical shocks 8 Neither main de...

Page 9: ...ith keloid Use a pacemaker Regularly taking anti inflammatory medication Sensitive problem skin Hypertrophic scar marks Red spot 2 8 Contraindications CoolShaping is a safe device yet treatment operat...

Page 10: ...3 1 Structure 3 Component CoolShaping System 10 CoolShaping LCD Monitor Handpiece cable Handpiece Key switch Handle...

Page 11: ...n 108mm W x 188mm D x 138mm H Dimension 118mm W x 220mm D x 142mm H Dimension 108mm W x 172mm D x 120mm H Large size Engineered with Integrated Technology Cryogenic Fat Reduction Vacuum LED Operators...

Page 12: ...Please consider the following electrical requirements before installing the system The AC line power requirements for the system are 100 V 220 240 V 50 Hz 60 Hz The power receptacle must be grounded C...

Page 13: ...ocation where the humidity is between 10 and 90 noncondensing Store the system where the air is free of corrosive substances such as salts or acids Store the system where there is a minimum of dust pa...

Page 14: ...ystem for functional operation of all components and software 5 1 About the Installation 5 Installation Turn the system off and disconnect the power cable before connecting or disconnecting the applic...

Page 15: ...e water connector holder Otherwise an accident caused by leakage may occur Before connecting do make sure that the condition of water connector holder is Normal If it is Not Normal condition press top...

Page 16: ...5 Installation 5 3 Fill up the water CoolShaping 16 Open backside cover Pulling the latch to open the back plate...

Page 17: ...oir with regular tap water Use only either distilled or deionized water CoolShaping 17 1 Open the Fill port by turning in a counterclockwise direction Fill the Water 2 Connect the funnel hose to Fill...

Page 18: ...t for water drainage If the device is not in use for a long period of time please drain the water and store the device 3 The water fills up the red line of the hose Fill water up and power on the Hand...

Page 19: ...le in the middle of device 5 5 Insert the Safety key Power on by press the power button at the lower back side of device and then turn the safety key switch clockwise to the power on 5 6 Turn on the P...

Page 20: ...espective socket and locate in their cradles 3 Turn on the system by pressing the power button turn the safety key in the right direction 6 2 2 Turn on the CoolShaping Once the system powers up bootin...

Page 21: ...low 1 Dual mode L R L R Both Left and Right applicators operate with synchronized same value 2 Single mode Left or Right Single L Left applicator operate alone R Right applicator operate alone During...

Page 22: ...me Display treatment time Time decrease increase button Select treatment time Time reset button Reset treatment time Vacuum level display Display vacuum level Level decrease increasebutton Select vacu...

Page 23: ...or Manual mode 1 L R mode 2 Left mode 3 Right mode Auto mode Manual mode 6 3 Auto Mode Screen 6 Operating Instructions Treatment step button Auto mode allows a process of going through STEP I STEP II...

Page 24: ...ter 45min of operation the device will stop operating Time decrease increase button Select treatment time Adjustment range 01min 60min Time reset button Reset treatment time and STEP set value Preset...

Page 25: ...treatment display Display applicator operating one of L R Left and Right Start Stop button Device in operation Operation Stopped Timer will be at pause Stop Operating Water level display Water level...

Page 26: ...Sound button ON OFF 6 3 Auto Mode Screen 6 Operating Instructions CoolShaping 26...

Page 27: ...Time decrease increase button Select treatment time Time reset button Reset treatment time Vacuum level display Display vacuum level level decrease increasebutton Select vacuum level Current treatmen...

Page 28: ...Vacuum pulse 4 kinds of pulse Cooling temperature Set cooling temperature Adjustment range 10 5 CoolShaping 28 Select one of following applicator mode as shown below Selected mode will be colored stri...

Page 29: ...nt time and STEP set value Preset 45min 6 4 Manual Mode Screen 6 Operating Instructions Vacuum level display Level decrease increase button Preset 5 Display vacuum level Select vacuum level Level can...

Page 30: ...de Screen 6 Operating Instructions Start Stop button Sound button CoolShaping 30 Device in operation Operation Stopped Timer will be at pause Water error display Water level warning Normal 1st Warning...

Page 31: ...ode Auto Manual Single Mode Right Mode Both of dual mode and single mode has each of its own pre selected Auto and Manual mode Auto mode Step 1 Step 2 Step 3 Manual mode Pulse Temperature and Vacuum l...

Page 32: ...matically selected if there will not be any mode changing action 3 After locating the CoolPad attach 2 applicators at target place and press Start to initiate the CoolShaping treatment 4 Default value...

Page 33: ...s automatically selected if there will not be any mode changing action 3 Press MANUAL soft key which is placed at the bottom right 4 Select desired choice of Vacuum pulse 5 Adjust Vacuum level 6 Attac...

Page 34: ...if there will not be any mode changing action 3 Attach an applicator at target area then press Start to initiate CoolShaping treatment 4 Default value is shown as above If operators care to adjust mo...

Page 35: ...ode changing action 3 Press MANUAL soft key which is placed at the bottom right 4 Select desired choice of Vacuum pulse 5 Adjust Vacuum level 6 Attach both applicators at their target treatment area t...

Page 36: ...e any mode changing action 3 Attach an applicator at target area then press Start to initiate CoolShaping treatment 4 Default value is shown as above If operators care to adjust more specifically in c...

Page 37: ...rom HOME screen 2 Auto Mode is automatically selected if there will not be any mode changing action 3 Press MANUAL soft key which is placed at the bottom right 4 Select desired choice of Vacuum pulse...

Page 38: ...available by START STOP button on the applicator Cooling Turn _ON Turn _OFF Vacuum Turn _ON Turn _OFF Applicator On Off Dual mode L R 2ea applicators are activated at the same time by Start Stop butto...

Page 39: ...device by pressing down the black lever into the side of this icon then turn the air filter in to the direction of right Check filters once per month 7 2 Cleaning Main Device Clean the outer surface...

Page 40: ...he display with a brief text message All error messages are listed in the following along with corrective action if applicable The following does not attempt to list all possible system failures Any e...

Page 41: ...ter level First warning If this symbols appears on the right side of the screen there is a shortage of water in the device However the device is operating normally Second warning If after the first wa...

Page 42: ...ng after you have confirmed patients good placement of the applicator and the patient is in a comfortable position Press start button 6 Check on the patient periodically during treatment CoolShaping 4...

Page 43: ...8 1 L R applicator 1 Abdomen 2 back Medium or Small Size 8 Treatment Guideline CoolShaping 43 Medium or Small Size...

Page 44: ...3 Hip 4 Thigh Saddlebag Medium Size Medium Size CoolShaping 44 8 1 L R applicator 8 Treatment Guideline Back...

Page 45: ...1 Abdomen 2 back Medium or Small Size Medium or Small Size 8 2 L or R applicator 8 Treatment Guideline CoolShaping 45...

Page 46: ...3 Hip 4 Thigh Medium or Large Size Medium or Large Size 8 2 L or R applicator 8 Treatment Guideline CoolShaping 46 Saddlebag Inner Thigh...

Page 47: ...ection to improper voltage or incorrect electrical line voltage malware reckless willful or intentional conduct Damages caused by a product or part that has been disconnected modified arbitrary repair...

Page 48: ...Tel 82 2 514 9713 Rep Fax 82 2 514 9716 E mail es esglobal co kr www esglobal co kr 10 Technical Specifications Applicators 1 Medium size 2 Small Large size Optional Vacuum 260mmHg Cooling Temperature...

Page 49: ...CoolShaping 49...

Reviews: