Operating Instructions
Safety System MGBS-P-I-AP…
22
(Translation of the original operating instructions) 2527247-01-09/19
12.2.1. Teaching in handle module
1. Establish teach-in standby:
-Devices in the condition as supplied: unlimited teach-in standby after switching on
-Interlocking module already taught in: teach-in standby is available for approx. 3 min. after switching on
¨
Teach-in standby indication, STATE LED flashes 3x repeatedly
2. Insert the tongue on the handle module during teach-in standby.
¨
The automatic teach-in operation starts (duration approx. 30 s).
During the teach-in operation the STATE LED flashes (approx. 1 Hz).
Alternate flashing of the STATE and DIA LEDs acknowledges the successful teach-in operation.
Teach-in errors are indicated by the illumination of the red DIA LED and a flashing code on the green State LED (see
6.4. Switching states on page 8
3. Switch off operating voltage UB (min. 3 s).
¨
The code of the handle module that was just taught in is activated in the interlocking module.
4. Switch on operating voltage UB.
¨
The device operates normally.
4.1.
Functional check
WARNING
Danger of fatal injury as a result of faults in installation and functional check.
Ì
Before carrying out the functional check, make sure that there are no persons in the danger zone.
Ì
Observe the valid accident prevention regulations.
4.1.1. Mechanical function test
The tongue on the handle module must slide easily into the actuating head. Close the guard several times to check the
function. For devices with mechanical release (emergency release or escape release), the correct function of the release
must be checked as well.
4.1.2. Electrical function test
After installation and any fault, the safety function must be fully checked. Proceed as follows:
1. Switch on operating voltage.
¨
The machine must not start automatically.
¨
The interlocking module carries out a self-test. The green STATE LED then flashes at regular intervals.
2. Close all guards.
¨
The machine must not start automatically.
¨
The green STATE LED illuminates continuously.
3. Enable operation in the control system.
4. Open the guard.
¨
The machine must switch off and it must not be possible to start it as long as the guard is open.
Repeat steps 2–4 for each guard.