Operating Instructions Safety Systems
MGB2-L1…-BR.-… / MGB2-L2…-BR.-… and MGB2-L1…-BP.-… / MGB2-L2…-BP.-…
50
(translation of the original operating instructions) 2500233-04-10/21
16. Technical data
NOTICE
If a product data sheet is included with the product, the information on the data sheet applies in case
of discrepancies with the operating instructions.
Parameter
Value
Unit
min.
typ.
max.
Housing material
Fiber glass reinforced plastic
Die-cast zinc, nickel-plated
Stainless steel
Dimensions
See chapter
7.4. Dimension drawing on page 15 (interlocking/locking module, without submodules)
Weight
Locking module
Handle module
Escape release
1.00
1.10
0.55
kg
Ambient temperature at UB = DC 24 V
-25 … +55
°C
Degree of protection
Cover not populated/populated with buttons/
indicators/selector switches/key-operated rotary
switches
IP65
Safety class
III
Degree of contamination
3
Installation orientation
Any
Locking force F
zh
acc. to EN ISO 14119
2,000
N
Connection
1 cable entry M20x1.5 with 4 socket connectors or plug connectors
Conductor cross-section (rigid/flexible)
- With ferrule acc. to DIN 46228/1
- With ferrule with collar acc. to DIN 46228/1
0.25 … 1.5 (AWG 23 … AWG 16)
0.25 … 1.5
0.25 … 0.75
mm²
Operating voltage UB
(reverse polarity protected, regulated, residual
ripple < 5%)
up to V1.0.4: 24 ±15% (PELV)
from V1.0.5: 24 -15% / +20% (PELV)
V DC
Current consumption I
UB
(at 20.4 V incl. FI1A/FI1B,
no load on any outputs)
80
mA
Operating voltage for guard locking solenoid IMP
(reverse polarity protected, regulated, residual
ripple < 5%)
up to V1.0.4: 24 ±15% (PELV)
from V1.0.5: 24 -15% / +20% (PELV)
V DC
Test pulses
Guard locking solenoid operating voltage IMP
5
ms
Test-pulse interval
Guard locking solenoid operating voltage IMP
100
ms
Current consumption I
IMP
- with energized guard locking solenoid
375
mA
External fuse
See chapter
13.4. Fuse protection for power supply on page 32
Safety outputs FO1A/FO1B
Semiconductor outputs, p-switching, short circuit-proof
Test pulses
< 300
µs
Test-pulse interval
Min. 100
ms
Output voltage U
FO1A
/ U
FO1B
1)
HIGH
U
FO1A
/ U
FO1B
UB-2V … U
B
LOW
U
FO1A
/ U
FO1B
0 … 1
V DC
Switching current per safety output
1 … 150
mA
Utilization category acc. to EN IEC 60947-5-2
DC-13 24 V 150 mA
Caution: Outputs must be protected by a free-wheeling diode in the case of inductive loads.
Monitoring outputs
- Output voltage
1)
- Max. load
p-switching, short circuit-proof
UB
- 2V … UB
Max. 50
mA
Rated insulation voltage U
i
75
V
Rated impulse withstand voltage U
imp
1.5
kV
Resilience to vibration
Acc. to EN IEC 60947-5-3
Switching frequency
0.25
Hz
EMC protection requirements
Acc. to EN IEC 60947-5-3
Ready delay (BR)
-
5
-
s
Risk time for single device
-
-
50
ms
Risk time delay per device
10
ms
Turn-on time
-
-
80
ms
Discrepancy time
-
-
10
ms