13.7.2. Deactivating guard lock monitoring
WARNING
Risk of injury due to inactive guard lock monitoring.
Ì
With inactive guard lock monitoring, the guard locking position does not influence the safety out-
puts. The guard can be opened immediately. This setting is not allowed to be used in applications
in which, e.g., there is a hazard due to overrunning machinery movement. With inactive guard lock
monitoring, guard locking must be used only for process protection.
1. Switch off power supply.
2. Set DIP switches 2, 5 and 8 as shown.
Deactivating guard lock monitoring
Activating guard lock monitoring
ON
3 4
6 7
8
5
2
1
ON
3 4
6 7
8
5
2
1
3. Switch on power supply for 5 s.
¨
The change is confirmed by positive acknowledgment.
4. Switch off power supply and set DIP switch 8 to OFF.
¨
The next time the device is started, it operates in the operating mode set.
13.7.3. Activating release monitoring
NOTICE
When release monitoring is active, the system enters into a latching fault when the escape release or
auxiliary release is actuated.
See
System status table
,
signal sequence incorrect
status (DIA red, Lock flashes 1 time).
1. Switch off power supply.
2. Set DIP switches 3 and 8 as shown.
Deactivating release monitoring
Activating release monitoring
ON
2
4
6 7
8
5
3
1
ON
2
4
6 7
8
5
3
1
3. Switch on power supply for 5 s.
¨
The change is confirmed by positive acknowledgment.
4. Switch off power supply and set DIP switch 8 to OFF.
¨
The next time the device is started, it operates in the operating mode set.