16. Troubleshooting and assistance
Simple errors (DIA flashing) are reset by opening and closing the guard. If the error is not reset by this action, proceed as
follows:
16.1. Resetting errors
Proceed as follows:
1. Open the guard.
2. Switch off operating voltage at the interlocking module for min. 3 seconds or connect 24 V to the input RST for min. 3
seconds.
Alternatively, the internal reset (see
) can be pressed for 3 seconds with a pointed
object, e.g. small screwdriver.
¨
The green LED (State) flashes quickly (approx. 5 Hz in case of BR configuration). A self-test is performed during this time
(approx. 5 s in case of BR configuration). The LED then cyclically flashes three times.
3. Close the guard.
¨
The system is in normal operation again.