Operating Instructions Safety Systems
MGB-L..B-EI-… (Ethernet/IP) and With Data Structure Type A
26
(translation of the original operating instructions) 2126330-10-03/21
Abbr.
Name
Data Type Safe signal Tag Definition
RM
RunMode
BOOL
No
Run Mode - Indicates the operating mode of the multifunctional gate box
0 = while restarting
1 = Run Mode after successful restarting of bus module
CF
ConnectionFaulted
BOOL
No
Connection Faulted - Indicates the state of the communication connection between the multifunctional gate
box and the controller.
0 = Connection of output data
1 = Connection of output data Faulted
DA
DiagnosticActive
BOOL
No
Diagnostic Active - Indicates whether the multifunctional gate box is faulted.
0 = No Fault
1 = Fault
DSC
DiagnosticSequenceCount
SINT
No
Diagnostic Sequence Count - Displays the total accumulated diagnostic counts.
Values range from 0…255.
FI.ES
EstopStatus
BOOL
Yes
E-stop Button Status
1 = Contacts Closed (E-stop not pressed)
0 = Contacts Open (E-stop pressed)
FI.EN
EnablingSwitchStatus
BOOL
Yes
Enabling Switch Status
1 = Switch Enabled
0 = Released
FI.MS0
ModeSelectPos1
BOOL
Yes
Mode Selector Switch Position 1
1 = Selector Switch in position 1
0 = Selector switch is not in position 1
FI.MS1
ModeSelectPos2
BOOL
Yes
Mode Selector Switch Position 2
1 = Selector Switch in position 2
0 = Selector switch is not in position 2
FI.MS2
ModeSelectPos3
BOOL
Yes
Mode Selector Switch Position 3
1 = Selector Switch in position 3
0 = Selector switch is not in position 3
FI.D
DoorStatus
BOOL
Yes
Door Status - position of the guard door
0 = guard door is OPEN
1 = guard door is CLOSED
FI.B
BoltStatus
BOOL
Yes
Bolt Status - position of the bolt actuator
0 = bolt is retracted
1 = bolt is extended
FI.L
SolenoidStatus
BOOL
Yes
Solenoid Status - position of the solenoid locking arm
0 = locking arm is in unlocked position
1 = locking arm is in locked position
FI.SK
InterlockStatus
BOOL
Yes
Interlock Status
0 = bolt retracted and/or door OPEN
1 = door is CLOSED and bolt is extended
FI.UK
GuardLockStatus
BOOL
Yes
Guard Lock Status
0 = door is OPEN, or door is CLOSED with bolt retracted, or door is CLOSED with bolt extended and
unlocked
1 = door is CLOSED, bolt is extended, and bolt is locked
Sxx.1
OpxPos1
BOOL
No
Operator Position 1
1 = Pressed (push button) or right position (selector switch)
0 = Released (push button)
or 2-position selector switch in middle position
or 3-position selector switch in midle or left position
x = 1, 2, 3, 4, 90, 91, 92, 93, 94, 95
Sxx.2
OpxPos2
BOOL
No
Operator Position 2
1 = left position (3-position selector switch)
0 = released push button
or 2 position selector switch in right or middle position
or 3 position selector switch in middle position
x = 1, 2, 3, 4, 90, 91, 92, 93, 94, 95
D.PF
PlausibilityFault
BOOL
No
Plausibility Fault - indicates a signal sequence error (lock module error), unlocking sequence
D.ES
EstopFault
BOOL
No
Estop Fault - indicates an E-stop specific fault
D.EN
EnablingSwitchFault
BOOL
No
Enabling Switch Fault - indicates an Enabling Switch specific fault
D.MS
ModeSelectFault
BOOL
No
Safe Mode Selector Switch Fault - indicates a Mode Selector Switch specific fault
D.OL
LockCommandFault
BOOL
No
Lock Command Fault - indicates a fault in the Lock Command
D.LT
CycleCount
BOOL
No
Cycle Count - indicates when the device has reached 1,000,000 switching cycles
0 = < 1,000,000 swtiching cycles of the solenoid
1 = > 1,000,000 switching cylcles of the solenoid
FaultCode
SINT
No
Fault Code - indicates the specific diagnostic message of the multifunctional gate box
FO.L
LockCommand
BOOL
Yes
Lock Command - control for switching the guard locking on and off
0 = Guardlocking is locked
1 = Guardlocking is unlocked
Hxx
OpxIndicator
BOOL
No
Operator Indicator - controls illumination of the operator
1 = illumination is turned ON
0 = illumination is turned OFF
x = 1, 2, 3, 4, 90, 91, 92, 93, 94, 95
STx
StacklightControl
BOOL
No
Stacklight Indicator - controls illumination of the stacklight
1 = illumination is turned ON
0 = illumination is turned OFF
x = 1, 2, 3, 4
Q.G
GeneralFaultAck
BOOL
No
General Fault Acknowledgement - resets the bus module
1=Reset of bus module
0=normal operation of device
Q.PF
PlausibilityFaultAck
BOOL
No
Plausibility Fault Acknowledgement - resets the lock module
1=Reset of locking module
0=normal operation of device
EN-Sx
EnablingSwitchOpxPos
BOOL
No
Enabling Switch Operator Position
1 = pressed (push button)
0 = released (push button)
EN-Hx
EnablingSwitchOpxIndicator BOOL
No
Enabling switch Operator Indicator - controls illumination of the operator
1 = illumination is turned ON
0 = illumination is turned OFF