![EUCHNER LCA 2 Series Operating Instructions Manual Download Page 53](http://html.mh-extra.com/html/euchner/lca-2-series/lca-2-series_operating-instructions-manual_2434781053.webp)
53
2504708-03-02/21 (translation of the original operating instructions)
Operating Instructions
Light Grids/Light Curtains LCA 2
EN
A distinction is made between two device types:
Light grids
produce a protective field consisting of 2 – 4 light beams. Due to the large spacing between the individual light
beams, these devices can be used only for body protection.
Light curtains
consist of a large number of light beams. These devices can detect different body parts depending on the
resolution (30 – 50 mm). A distinction is made between hand and body protection.
Light grid
2 - 4 light beams
Light curtain
Large number of light beams, specification as »resolution«
Figure 3:
Light grid, light curtain
6.1. Versions at a glance
Light curtains LCA 2 are available in the following resolutions:
Ì
30 mm (protected heights from 160 mm to 1,810 mm)
HAND PROTECTION
Ì
40 mm (protected heights from 160 mm to 1,810 mm)
HAND PROTECTION
Ì
50 mm (protected heights from 160 mm to 1,810 mm)
ARM AND LEG PROTECTION
Light grids LCA 2 are available in the following versions:
Ì
2 beams (500 mm between the beams)
BODY PROTECTION / ACCESS CONTROL
Ì
3 beams (400 mm between the beams)
BODY PROTECTION / ACCESS CONTROL
Ì
4 beams (300 mm between the beams)
BODY PROTECTION / ACCESS CONTROL
Table 1: Terminology
Term
Definition
Resolution
Lens s lens diameter
ESPE
Electro-sensitive protective equipment
FE
Function earth
FO1A/FO1B
Safety outputs
Multiple systems
Use of several LCA systems in parallel
Table 2: Type designations
Designation
Definition
LCA 2 T
Transmitter unit
LCA 2 R
Receiver unit
LCA 2 TR
Transmitter/receiver set