![EUCHNER HBAS 094594 Manual Download Page 75](http://html1.mh-extra.com/html/euchner/hbas-094594/hbas-094594_manual_2434938075.webp)
EUCHNER
Hand-Held Pendant Station
HBAS-094594
095640-02-02/06
Subject to technical modifications
Page 35 / 40
10.3 Overview of commands
Identifier
byte
Command
byte
Description
Parameter:
21H
Cursor to the next character
22H
Cursor to the previous character
23H
Cursor one line down
24H
Cursor one line up
25H
Cursor at the start of the display
26H
Cursor at the start of the line
27H
Cursor at a specific position
Line, column
28H
Clear the current cursor position
29H
Clear to the end of the line
2AH
Clear to the end of the display
2BH
Clear the entire display
2CH
Clear a screen area
Start line, start column,
end line, end column
40H
Inverse on: all subsequent characters
are output inverse
41H
Inverse off
42H
Flashing on: all subsequent characters
are output flashing
43H
Flashing off
08H
Definition of an item of text
Text number,
font size, line,
column, text
49H
Output of a previously defined item of text
Text number
4AH
Definition of an area
Area number, start line, start
column, end line, end column
4BH
Clear a previously defined area
Area number
4CH
Inverse display of an area
Area number
4DH
Flashing display of an area
Area number
4EH
Inv. + flashing display of an area
Area number
4FH
Normal display of an area
Area number
50H
51H
Selection "small font"
Selection "large font"
6CH
80H ... FFH ASCII character set
23H
Status poll (keys 30H ... 44H and
error byte 31H ... 36H are sent)
52H
Continuous sound on
Continuous sound off
Pulsed sound on
Pulsed sound 0.5 s
30H
31H
32H
33H
none
53H
Transfer parameter settings
PIN, priority,
pulse generator active,
pulse generator delay,
key assignment,
pulse generator frequency,
key click