21
2123041-08-01/21 (translation of the original operating instructions)
Operating Instructions
Transponder-Coded Safety Switch CTP-AR
EN
10.6. Connector assignment of safety switch CTP-…-AR-…-SAB-… with plug connectors
2 x M12
Wiring diagram A
Plug connector
(view of connection side)
Pin
Designation
Function
Conductor coloring
of connecting
cable
1)
2 x M12
X2.5
X1.8
X1.5
X1.6
X1.7
X1.2
X2.4
X2.3
X2.1
X2.2
X1.4
X1.3
X1.1
X 1.1
FI1B
Enable input, channel B
WH
X 1.2
UB
Electronics operating voltage, 24 V DC
BN
X 1.3
FO1A
Safety output, channel A
GN
X 1.4
FO1B
Safety output, channel B
YE
X 1.5
OL
Guard lock monitoring output
GY
X 1.6
FI1A
Enable input, channel A
PK
X 1.7
0VUB
Electronics operating voltage, 0 V DC
BU
X 1.8
RST
Reset input
RD
X 2.1
IMM
Solenoid operating voltage, 0 V DC
BN
X 2.2
OD
Door position monitoring output
WH
X 2.3
OI
Diagnostic monitoring output
BU
X 2.4
IMP
Solenoid operating voltage, 24 V DC
BK
X 2.5
-
n. c.
GY
1) Only for standard EUCHNER connecting cable.
10.7. Connector assignment of safety switch CTP-…-AR-…-SH-… with plug connector
M23 (RC18)
Wiring diagram B
Plug connector
(view of connection side)
Pin
Designation
Function
Conductor coloring
of connecting
cable
1)
M23 (RC18)
With shield
spring
18
19
15
12
11
9
5
4
3
2
1
17
16
14
13
6
10
8
7
1
IMP
Solenoid operating voltage, 24 V DC
VT
2
FI1A
Enable input, channel A
RD
3
FI1B
Enable input, channel B
GY
4
FO1A
Safety output, channel A
RD/BU
5
FO1B
Safety output, channel B
GN
6
UB
Electronics operating voltage, 24 V DC
BU
7
RST
Reset input
GY/PK
8
OD
Door position monitoring output
GN/WH
9
OI
Diagnostic monitoring output
YE/WH
10
OL
Guard lock monitoring output
GY/WH
11
-
n.c.
BK
12
FE
Function earth
(must be connected to meet the EMC requirements)
GN/YE
13
-
n.c.
PK
14
-
n.c.
BN/GY
15
-
n.c.
BN/YE
16
-
n.c.
BN/GN
17
-
n.c.
WH
18
IMM
Solenoid operating voltage, 0 V DC
YE
19
0VUB
Electronics operating voltage, 0 V DC
BN
1) Only for standard EUCHNER connecting cable.