21
2539116-02-09/21 (translation of the original operating instructions)
Operating Instructions
Transponder-Coded Safety Switch CTM-L2-AS1B
EN
12.4. Technical data for actuator A-B-A1-A1-…
Parameter
Value
Unit
min.
typ.
max.
Material
- Housing
Ultradur black
- Ball holder
Stainless steel
- Elastomer
A-B-A1-161642: FKM red / A-B-A1-161643: FKM blue
Resistance
Resistant to chemicals and oil
Food safe
DIN EN 1672-2, DIN EN ISO 14159, PAH category 3
Weight
0.0194
kg
Ambient temperature
-20
-
+60
°C
Degree of protection
IP65/IP67/IP69/IP69K
Mechanical life
1 x 10
6
Locking force, max.
1,300
N
Locking force F
Zh
1,000
N
Installation orientation
Any
Overtravel
2
mm
Power supply
Inductive via read head
12.4.1. Dimension drawing for actuator A-B-A1-A1-…
Remove the set-up tool after mounting,
electrical connection and setup.
Tip!
Remove the set-up tool after mounting the safety switch and actuator.