Operating Instructions
Transponder-Coded Safety Switch CTM-L2-AS1B
16
(translation of the original operating instructions) 2539116-02-09/21
11. System status table
Operating mode
Actuator/door position
LED indicator
Output
State
ST
ATE/DIA (gr
een)
ST
ATE/DIA (r
ed)
LOCK (yellow)
Normal operation
off
5 Hz
Power Up
closed
Normal operation, door closed and locked
closed
1 x in-
verse
Normal operation, door closed and
not
locked
open
1 x
Normal operation, door open
open
1 x
1 x
Normal operation, door open, ready for guard locking
Teach-in operation
(only unicode)
open
3 x
Device in teach-in standby
closed
1 Hz
Teach-in operation
X
Positive acknowledgment after completion of teach-in operation
Fault display
X
1 x
or
1 x in-
verse
Error in the teach-in operation (only unicode)
Actuator removed from the actuating range prior to the end of the teach-in
operation or disabled actuator detected
X
3 x
Transponder error
(e.g. actuator faulty)
X
5 x
Environment errors
(e.g. operating voltage or operating temperature too high)
X
1 x
Plausibility errors
X
X
Internal error
X
1 x in-
verse
1 x in-
verse Locking element stuck
Key to symbols
LED not illuminated
LED illuminated
1 x inverse
LED illuminated, briefly goes off 1 x
5 Hz
LED flashes at 5 Hz
3 x
LED flashes three times, and this is then repeated
LEDs flash alternately
X
Any state
When STATE/DIA flashes red inversely once, the fault display can generally be reset by opening and closing the guard after
remedying the cause. If the fault is still displayed afterward, as well as for all other fault displays, briefly interrupt the power
supply. Contact the manufacturer if the fault display is not reset after restarting.
Important!
If you do not find the displayed device status in the system status table, this indicates an internal device
fault. In this case, you should contact the manufacturer.