![EUCHNER CET.-AR Series Operating Instructions Manual Download Page 41](http://html.mh-extra.com/html/euchner/cet-ar-series/cet-ar-series_operating-instructions-manual_2434843041.webp)
41
2110788-13-03/20 (Translation of the original operating instructions)
Operating Instructions
Transponder-Coded Safety Switch CET.-AR-…
EN
12. System status table
Operating mode
Actuator/door position
Safety outputs OA and
OB
Monitoring output OUT
Door monitoring output OUT D
(
only CET3 and CET4)
LED indicator
Output
State
ST
ATE (gr
een)
DIA (r
ed)
Self-test
X
off
off
off
10 Hz
(10 s)
Self-test after power-up
Normal operation
closed
on
on
on
Normal operation, door closed and locked
closed
off
on
on
1 x in-
verse
Normal operation, door closed and locked, safety outputs not switched
because:
- Preceding device in the switch chain signals
door open
(only with series
connection)
- Feedback loop/start button not closed (if fitted)
closed
off
off
on
1 x
Normal operation, door closed and
not
locked
open
off
off
off
1 x
Normal operation, door open
Teach-in operation
(only unicode)
open
off
off
off
3 x
Door open; device is ready for teach-in for a new actuator
(only short time after power-up)
closed
off
off
off
1 Hz
Teach-in operation
X
off
off
off
1 x
Acknowledgment after successful teach-in operation (DIA flashes once, no
repetition)
Fault display
X
off
off
off
1 x
Fault in teach-in operation (only unicode)
For autom. teach-in:
- Actuator removed from the actuating range prior to the end of the teach-
in operation
For teach-in input:
- Actuator removed from the actuating range prior to the end of the teach-
in operation
- Disabled actuator within the actuating range
- Most recently taught-in actuator within the actuating range
- No actuator detected after 3 min.
X
off
off
off
2 x
Input fault
(e.g. missing test pulses, illogical switch state from previous switch in the
switch chain)
X
off
off
off
3 x
Actuator faulty
X
off
off
off
4 x
Output fault
(e.g. short circuit, loss of switching ability)
X
off
off
off
5 x
Internal error, e.g.:
- Component faulty
- Data error
- Impermissible pulsing on U
B
- Voltage applied to the RST input for less than 3 s
X
off
off
off
X
X
Internal error
Key to symbols
LED not illuminated
LED illuminated
10 Hz (10 s)
LED flashes for 10 s at 10 Hz
3 x
LED cyclically flashes three times
X
Any state
After the cause has been remedied, faults can generally be reset by opening and closing the guard. If the fault is still dis-
played afterward, use the reset function or briefly interrupt the power supply. Please contact the manufacturer if the fault
could not be reset after restarting.
Important!
If you do not find the displayed device status in the system status table, this indicates an internal device
fault. In this case, you should contact the manufacturer.