
13
2120545-05-08/18 (translation of the original operating instructions)
Operating Instructions
Non-Contact Safety Switch CES-I-AS2A-M-C04
EN
11. Technical data
NOTICE
If a data sheet is included with the product, the information on the data sheet applies.
11.1. Technical data of safety switch CES-I-AS2A-M-C04
Parameter
Value
Unit
min.
typ.
max.
Housing material
Plastic PBT
Rubber-support material
NBR 80 ±5 Shore
Fixing screw tightening torque
-
-
0.8
Nm
Dimensions
42 x 25 x 18
mm
Weight (without connection cable)
0.04
kg
Ambient temperature at U
B
= DC 30 V
-25
-
+65
°C
Storage temperature
-25
-
+70
Degree of protection
IP67
Safety class
III
Degree of contamination
3
Installation position
Any
Installation method
Non-flush
Connection
M8 plug connector, 3-pin
For the approval according to UL the following applies
Operation with UL-class 2 power supply only
Rated insulation voltage U
i
-
-
300
V
Rated impulse withstand voltage U
imp
-
-
1.5
kV
Resilience to vibration
In acc. with EN IEC 60947-5-2
Switching frequency
-
-
1
Hz
Ready delay
-
0.5
-
s
Risk time
-
-
260
ms
Switch-on time
300
ms
AS-Interface data
EA code: 0
ID code: B
AS-i operating voltage
19
-
31.6
DC V
Total current consumption
-
-
50
mA
Valid AS-Interface addresses
1 - 31
AS-Interface inputs
Acc. to AS-Interface Safety at Work
Door monitoring contact
D0 - D3
Reliability values according to EN ISO 13849-1
Category
4
Performance Level
PL e
PFH
D
4.5 x 10
-9
/ h
Mission time
20
years