Operating Instructions
Non-Contact Safety Switch CES-I-AR-.-C04/C14-…
34
(Translation of the original operating instructions) 2119563-12-03/20
12.6. Technical data for actuator CES-A-BBN-161502
Parameter
Value
Unit
min.
typ.
max.
Housing material
PBT plastic
Dimensions
42 x 25 x 12
mm
Weight
0.025
kg
Ambient temperature
- 25
-
+ 70
°C
Degree of protection
IP65/IP67
Installation position
Active face opposite read head
Power supply
Inductive via read head
12.6.1. Dimension drawing
Active face
32
42
25
12,4
B
B
12
3
11,3
4,5
B-B
NOTICE
Ì
2 safety screws M4x14 included
12.6.2. Operating distances
Actuating range for center offset m = 0
Installation position
Parameter
Value
Unit
A
B
min.
typ.
max.
Operating distance
-
30
-
mm
Assured operating distance s
ao 1)
15
-
-
Switching hysteresis
1)
1
2
-
Assured release distance s
ar
- in x/z direction
- in y direction
-
-
-
-
69
77
1) On approach in z direction
Installation position
Parameter
Value
Unit
C
D
min.
typ.
max.
Operating distance
-
25
-
mm
Assured operating distance s
ao 1)
10
-
-
Switching hysteresis
1)
1
2
-
Assured release distance s
ar
- in x/z direction
- in y direction
-
-
-
-
63
72
1) On approach in x direction