![EUCHNER CES-I-AP-C04 Series Operating Instructions Manual Download Page 22](http://html.mh-extra.com/html/euchner/ces-i-ap-c04-series/ces-i-ap-c04-series_operating-instructions-manual_2434836022.webp)
Operating Instructions
Non-Contact Safety Switch CES-I-AP-.-C04/C14-…
22
(Translation of the original operating instructions) 2115159-13-03/20
12.2. Technical data for safety switch CES-I-AP-.-C14-…
Parameter
Value
Unit
min.
typ.
max.
Housing material
Two-component epoxy resin
Dimensions
116 x 30 x 23
Weight (device without connecting cable)
0.7
kg
Ambient temperature at U
B
= DC 24 V
0
-
+ 50
°C
Storage temperature
- 40
-
+ 70
Degree of protection
IP65/IP67/IP69/IP69K
Safety class
III
Degree of contamination
3
Installation orientation
Any
Mounting method
Non-flush
Connection
Connecting cable PUR with flying lead, 5 x 0.25 mm²
Operating voltage U
B
(regulated, residual ripple < 5%)
24 ± 15% (PELV)
V DC
Current consumption
-
-
35
mA
External fuse
(operating voltage)
0.25
-
8
A
Safety outputs FO1A/FO1B
Semiconductor outputs, p-switching, short circuit-proof
- Output voltage U(FO1A)/U(FO1B)
1)
HIGH
U(FO1A)
U
B
-1.5
-
U
B
V DC
HIGH
U(FO1B)
LOW
U(FO1A)/U(FO1B)
0
1
Switching current per safety output
1
-
150
mA
Utilization category acc. to EN IEC 60947-5-2
DC-13 24 V 150 mA
Caution: Outputs must be protected by a free-wheeling diode in the case of inductive loads.
Off-state current I
r
2)
≤ 0.25
mA
Monitoring output DIA
1)
p-switching, short circuit-proof
- Output voltage
0.8 x U
B
-
U
B
V DC
- Max. load
-
-
50
mA
Rated insulation voltage U
i
-
-
300
V
Rated impulse withstand voltage U
imp
-
-
1.5
kV
Resilience to vibration
Acc. to EN IEC 60947-5-2
Switching frequency
-
-
1
Hz
Repeat accuracy R
acc. to EN IEC 60947-5-2
≤
10
%
EMC protection requirements
Acc. to EN IEC 60947-5-3
Ready delay
-
0.5
-
s
Risk time
-
-
260
ms
Turn-on time
-
-
300
ms
Discrepancy time
-
-
10
ms
Test-pulse duration
0.3
3)
ms
Test-pulse interval
140
ms
Reliability values acc. to EN ISO 13849-1
Category
4
Performance Level
PL e
PFH
D
4.1 x 10
-9
Mission time
20
years
1) Values at a switching current of 50 mA without taking into account the cable length.
2) Maximum current at an output in switched-off state.
3) Applies to a load with C < 30 nF and R < 20 kΩ.