Operating instructions
Non-Contact Safety System CES-AZ-UES-…
6
(Translation of the original operating instructions) 2105274-12-08/20
Important!
Ì
The user is responsible for the proper integration of the device into a safe overall system. For this
purpose, the overall system must be validated, e.g. in accordance with EN ISO 13849-2.
Ì
Correct use requires observing the permissible operating parameters (see technical data).
Ì
If a data sheet is included with the product, the information on the data sheet applies.
Ì
It is only allowed to use components that are permissible in accordance with the table below.
Table 1: Possible combinations for CES components
Evaluation unit
Read head
Actuator
CES
-A-BSP-104970
104970
CES
-A-BBN-106600
106600
CES
-A-BDN-06-104730
104730
CES
-A-BBA
071840
CES
-A-BCA
088786
CES
-A-BQA
098108
CES
-A-BDA-20
084720
CES
-A-BDA-18
156935
CES
-A-BMB
077791
CEM-A-BE05
094805
CEM-A-BH10
095175
CET
-A-BWK-50X
096327
CKS-A-BK1…
CKS key
CES-AZ-UES-01B
105139
CES-AZ-UES-02B
105140
CES-AZ-UES-04B
105141
CES-A-LSP-…
All items
20
CES-A-LNN-…
All items
15
19
CES-A-LCA-…
All items
15
15
16
16
CES-A-LNA-…
All items
15
15
16
16
CES-A-LQA-SC
095650
15
15
23
CES-A-LMN-SC
077790
8
8
9
9
5
CEM-A-LE05K-S2
094800
CEM-A-LE05R-S2
095792
CEM-A-LH10K-S3
095170
CEM-A-LH10R-S3
095793
CET1-AX-LRA-…
095735
CET1-AX-LDA-…
100399
CKS-A-L1B-…
113130
l
Key to symbols
l
Combination possible
15
Combination possible, typ. switch-on distance 15 mm
Combination possible, guard locking for process protection
Combination possible, guard locking for personnel protection
Combination not permissible