12.4. Technical data of actuator CES-A-BPA
Parameter
Value
Unit
min.
typ.
max.
Housing material
PBT
Dimensions
40 x 40 x 10
mm
Weight
0.025
kg
Ambient temperature
- 25
-
+ 70
°C
Degree of protection
IP65/IP67/IP69/IP69K
Installation orientation
Active face opposite read head
Power supply
Inductive via read head
12.4.1. Dimension drawing
30
±0,1
40
- 0,25
0
CES-A-BPA-098775
IP67
CD
10
4
Ø
5,2
Active face
Active face
NOTICE
2 safety screws M5x10 included.
12.4.2. Operating distances
Actuating range for center offset m = 0
1)
Parameter
Value
Unit
min.
typ.
max.
Operating distance
-
22
-
mm
Assured operating distance s
ao
18
-
-
Switching hysteresis
1
2
-
Assured release distance s
ar
-
-
58
1) The values apply to surface mounting of the actuator on metal.