![EUCHNER CES-A-UBA-01 Operating Instructions Manual Download Page 30](http://html.mh-extra.com/html/euchner/ces-a-uba-01/ces-a-uba-01_operating-instructions-manual_2434754030.webp)
Operating instructions
Non-Contact Safety System CES-A-UBA-01/CES-A-UBA-01B
30
(Translation of the original operating instructions) 2097097-17-08/20
11.7. Actuator CES-A-BQA
Ì
Cube-shaped design 50 x 50 mm
Dimension drawing for CES-A-BQA
40
±0,15
50
0,25
0
40
±0,15
50
0,25
0
6
20,2
Ø
4,5
-
-
Active face
Technical data
Parameter
Value
Unit
min.
typ.
max.
Housing material
Fortron, reinforced thermoplastic, fully encapsulated
Dimensions
50 x 50 x 20.2
mm
Weight
0.07
kg
Ambient temperature
-25
-
+70
°C
Degree of protection
IP67
Installation orientation
Active face opposite read head
Power supply
Inductive via read head