![EUCHNER CES-A-UBA-01 Operating Instructions Manual Download Page 23](http://html.mh-extra.com/html/euchner/ces-a-uba-01/ces-a-uba-01_operating-instructions-manual_2434754023.webp)
23
2097097-17-08/20 (Translation of the original operating instructions)
Operating instructions
Non-Contact Safety System CES-A-UBA-01/CES-A-UBA-01B
EN
11.4. Read head CES-A-LCA-…
Ì
Cube-shaped design 42 x 25 mm
Ì
PE-HD plastic housing material, suitable for use in aggressive media (e.g. acids, alkalis)
Dimension drawing
32
42
48
25
31
l
12
14
4,6
∅
8
∅
4,
5
± 0,1
Active face
Active face
2 M4 x 14 safety screws included
Flat seal
NOTICE
The flat seal provided must be used during assembly.
Typical actuating range
With evaluation unit CES-A-UBA-01 and actuator CES-A-BCA
-8
-4
-6
-2
2
6
4
8
0
2
4
6
8
Centre offset m [mm]
Distance s [mm]
OFF
ON
Actuator
Read head
s
m
Hysteresis
Switch-on
distance
ON
OFF
Hysteresis
Distance s
S
ao
Output stage
Switch-off
distance
OFF
With evaluation unit CES-A-UBA-01B and actuator CES-A-BCA
Side
lobe
N
-10
-15
-5
0
Centre offset m [mm]
Distance s [mm]
OFF
ON
Switch-on
distance
ON
OFF
Hysteresis
Distance s
S
ao
Output state
Switch-off
distance
OFF
Hysteresis
-20
5
20
15
10
5
10
15
20
Side
lobe
N
Actuator
Read head
s
m
NOTICE
For a side approach direction for the actuator and read head, a minimum distance of s = 3 mm must
be maintained so that the actuating range of the side lobes is not entered.
Approvals