23
2110182-09-12/18 (Translation of the original operating instructions)
Operating Instructions
Non-Contact Safety Switch CES-A-C5H-EX
EN
13.1.1. Technical data for safety switch CES-A-C5H-EX
Parameter
Value
Unit
min.
typ.
max.
Housing material
PBT GF30
Dimensions
According to EN 60947-5-2
mm
Weight
0.4
kg
Ambient temperature at U
B
= DC 24 V
-20
-
+50
°C
Degree of protection
IP65/IP 67
Degree of contamination
3
Rated insulation voltage U
i
-
-
300
1)
V
Rated impulse withstand voltage U
imp
-
-
1.5
kV
Rated conditional short-circuit current
100
A
Resilience to vibration
According to EN 60947-5-2
Installation position
Any
Connection
M12 plug connector, 8-pin, screen can be applied
Operating voltage U
B
(regulated, residual ripple < 5%)
21
24
27
V DC
For the approval according to UL the following applies
Operation only with UL class 2 power supply or equivalent measures
Current consumption
80
mA
Switching load according to UL
max. DC 24 V, class 2
External fuse (operating voltage U
B
)
0.25
-
8
A
Power supply for load U(+LA)/U(+LB)
18
-
27
V DC
Safety outputs (LA/LB, 2 semiconductor outputs, p-switching,
short circuit-proof, electrically decoupled)
- Output voltage U(LA/U(LB)
2)
HIGH U(LA)
U(+LA) - 1.5
-
U(+LA)
HIGH U(LB)
U(+LB) - 1.5
-
U(+LB)
V DC
LOW U(LA)/U(LB)
0
-
1
Switching current per safety output
1
-
100
mA
External fuse (U(+LA)/U(+LB), safety circuit
100 mA medium slow-blow
Utilization category according to EN 60947-5-2
DC-13 24 V 100 mA
Monitoring output (OUT, semiconductor output, p-switching,
short circuit-proof)
- Output voltage
0.8 x U
B
-
U
B
V DC
- Max. load
-
-
20
mA
Risk time
3)
-
-
180
ms
Discrepancy time
-
-
120
ms
Ready delay
4)
-
-
3
s
Dwell time
5)
0.5
-
-
s
Switching frequency
-
-
1
Hz
Repeat accuracy R acc. to EN IEC 60947-5-3
≤
10
%
Mounting distance between 2 read heads or 2 actuators
80
-
-
mm
EMC protection requirements
Acc. to EN 60947-5-3
LED displays
STATE
LED green: Normal operation
Flashing:
Teach-in
operation
OUT/ERROR LED yellow: Actuator detected
OUT/ERROR LED red:
- EMC interference
-
Internal
electronics
fault
-
Invalid
teach-in
operation
Reliability values acc. to EN ISO 13849-1
Category
4
Performance Level (PL)
PL e
PFH
D
3.7 x 10
-9
/ h
Diagnostic coverage DC
99
%
MTTF
D
644
years
Mission time
20
years
1) Tested by employers’ liability insurance association up to 75 V.
2) Values at a switching current of 50 mA without taking into account the cable length.
3) Maximum switch-off delay for the safety outputs following removal of the actuator.
4) After the operating voltage is switched on, the semiconductor outputs are switched off and the monitoring outputs are set LOW during the ready delay.