Operating Instructions
Non-Contact Safety Switch CES-A-C5H-EX
22
(Translation of the original operating instructions) 2110182-09-12/18
13. Technical data
NOTICE
If a data sheet is included with the product, the information on the data sheet applies.
13.1.
Approvals
Safety switch CES-A-C5H-EX
Ì
Read head and evaluation unit integrated in the normal housing
Ì
Semiconductor output
Ì
M12 plug connector
ATEX rating
II 3G Ex ic ec IIB T5 Gc X
II 3D Ex ic tc IIIC T90°C Dc X
Dimension drawing
30
±0,1
Ø 5,3
7,3
40
45,5
60
±0,1
165
46
40
40
46
57,5
13
M12x1
44,5
34,5
118
Active face
Active face
Protective plate
Grounding terminal
Ground the protective plate via cable
to prevent electrostatic charging.
Cable cross-section 4 … 6 mm²
y
LED GN
LED RD/YE
Switching characteristics
Ì
2 safety outputs
(semiconductor outputs)
Ì
One door monitoring output
(semiconductor output, not a safety
output)
Guard
closed
(actuator detected)
open
(actuator not in the operating
distance)
Read head Actuator
Read head
+LA
LA
+LB
LB
24 V
OUT
+LA
LA
+LB
LB
24 V
OUT