Operating Instructions
Transponder-Coded Safety Switch CTP/CTA-L1/2-BP
14
(translation of the original operating instructions) 2537377-01-05/21
7.4.1. Laying wire front release
Important!
Ì
Loss of the release function due to mounting errors, damage or wear.
Ì
Check the release function every time after mounting.
Ì
When routing the wire front release, ensure that it operates smoothly.
Ì
Observe the min. bending radius (100 mm) and minimize the number of bends.
Ì
The switch is not allowed to be opened.
Ì
Please observe the notes on the enclosed data sheets.
8. Changing the approach direction
The approach direction needs to be changed only if the switch is to be approached from the rear.
Proceed as follows:
1. Remove the screws from the safety switch.
2. Set the required direction.
3. Tighten the screws with a torque of 1.2 Nm.
C
B
D
A
Fig. 1:
Changing the approach direction