12. Setup
DANGER
Danger to life due to tampering.
Ì
Unused keys must be rendered unusable or protected against unauthorized access to prevent by-
passing the safety function.
Ì
If master keys or replacement keys are used, the operating organization must take suitable organi-
zational measures and use a corresponding risk assessment to prevent the system’s safety function
from being bypassed. For this purpose, observe the information in ISO/TS 19837.
12.1. Configuring the device and teaching-in the key for the first time
The device must be configured and the key must be allocated to the key adapter before the system forms a functional unit.
The function is defined during configuration using the key. Configuration and the teach-in operation occur simultaneously in
the delivery state or after a factory reset.
Key
Function
A-FLX-K-0A-RD-168921
1 key per packaging unit
A-FLX-K-0B-…
Several keys per packaging unit, with identical key code and different key identification
WARNING
Danger to life due to improper use
Ì
During the initial configuration or reconfiguration after a factory reset, ensure that all risk assessment
measures for the selected function are performed.
Important!
Ì
If the key to be taught-in is in the key adapter for less than 30 s, the device will not be configured
and the key will not be activated.
Ì
For keys of version A-FLX-K-0B-RD-…: Only one key per packaging unit has to be taught-in. All other
keys from the same package can be used without an additional teach-in operation.
Prerequisite:
Ì
The device is in the delivery state. A factory reset must be performed before a preconfigured device can be reconfigured
13. Factory reset on page 28).
Ì
The device is isolated from the operating voltage.
1. Make sure that no key is inserted.
2. Connect operating voltage to the key adapter.
¨
The LED flashes white quickly. The device is carrying out a self-test.
¨
The LED flashes white slowly. The device is in unlimited teach-in standby.
3. Insert a key.
¨
The teach-in operation begins. The LED alternately flashes white/violet slowly.
¨
The teach-in operation ends after approx. 30 s. The LED alternately flashes green/blue quickly (approx. 3 Hz).
4. Switch off operating voltage U
B
for at least 3 s.
¨
The code of the taught-in key is activated in the key adapter. The key is valid.
5. Switch on operating voltage U
B
.
¨
The device operates normally.