15
2540772-01-11/21 (translation of the original operating instructions)
Operating Instructions Bus Module
MBM-EC-..-MLI-… (EtherCAT)
EN
9. Controls and indicators
9.1.
DIP switches
These DIP switches have the following functions:
Ì
Setting the device’s FSoE slave address
Ì
Hardware reset to restore the device to the factory settings
Ì
Activating the device web interface
A0 RST
OFF
ON
1
2
3
4
5
6
7
8
9
10 11 12
ON
CTS
Default: 000
00‘0000‘0000
WWW
A1
A2
A3
A4
A5
A6
A7
A8
A9
Switch
Description
A0 … A9
Address switch, bits zero to nine
For binary setting of the FSoE address
(factory setting: 0000000000)
RST
Factory reset
(factory setting: off)
For information on the factory reset, see
WWW
Activate device web interface with extended
diagnostic options.
(factory setting: off)
For information on the device web interface,
.
9.2.
LED displays
The LEDs indicate the device status and the communication status.
LED
Description
Bus module MBM
L/A IN
Connection correct: statically On
Data transfer: flashing at 10 Hz
Color: green
EC STAT
Normal state: statically On
Flashing codes according to EtherCAT specification
Color: green/red
L/A OUT
Connection correct: statically On
Data transfer: flashing at 10 Hz
Color: green
FSoE
Normal state: statically On
Color: green
FSoE inactive/passivated: statically On
Color: yellow
FSoE Reset/Init State: flashing
Color: yellow
FSoE error: statically On
Color: red
FSoE – no connection to control system: Off
DIA
Indicates errors
Color: red
MAINT
Indicates the error flashing code
Color: red/green/yellow
SF
System fault:
13. Diagnostics, troubleshooting and aids
Color: red
Power
Power Up: flashing at 5 Hz
Normal state: statically On
Color: green