Operating Instructions
Safety System MGBS-P-L.-AR…
38
(Translation of the original operating instructions) 2527246-01-08/19
14. Technical data
NOTICE
If a data sheet is included with the product, the information on the data sheet applies.
14.1. Technical data for locking module MGBS-AR
Parameter
Value
Unit
min.
typ.
max.
General
Material
- Switch head
- Switch housing
Die-cast zinc
Reinforced thermoplastic
Installation orientation
Any
Degree of protection
with plug connector M12
IP 67/IP 69/IP 69K
with plug connector M23
IP67
(screwed tight with the related mating connector)
Safety class according to EN IEC 61558
III
Degree of contamination
3
Mechanical life
1 x 10
6
operating cycles
Ambient temperature at UB = 24 V
-20
-
+55
°C
Handle module approach speed, max.
20
m/min
Actuating/extraction/retention force at 20 °C
10/20/20
N
Locking force F
max
1)
3,900
N
Locking force F
Zh
1)
according to EN ISO 14119
F
Zh
= F
max
/1.3 = 3,000
N
Weight
Approx. 0.42
kg
Connection (depending on version)
2 plug connectors M12, 5- and 8-pin / 1 plug connector RC18, 19-pin
Operating voltage UB (reverse polarity protected, regulated,
residual ripple < 5 %)
24 ± 15% (PELV)
V DC
Current consumption I
UB
40
mA
For the approval according to UL the following applies
Operation only with UL class 2 power supply, or equivalent measures
Switching load according to UL
DC 24 V, class 2
External fuse (operating voltage UB)
2)
0.25
-
8
A
External fuse (solenoid operating voltage IMP)
2)
0.5
-
8
A
Rated insulation voltage U
i
-
-
50
V
Rated impulse withstand voltage U
imp
-
-
0.5
kV
Rated conditional short-circuit current
100
A
Resilience to vibration
Acc. to EN 60947-5-3
EMC protection requirements
Acc. to EN 60947-5-3
Ready delay
-
8
11
s
Risk time for single device
-
-
260
ms
Risk time delay per device
5
ms
Switch-on time
-
-
400
ms
Discrepancy time
-
-
10
ms
Test-pulse duration
1
ms
Frequency band
120 … 130
kHz
Safety outputs FO1A/FO1B
Semiconductor outputs, p-switching, short circuit-proof
- Output voltage U
FO1A
/U
FO1B
3)
V DC
HIGH U
FO1A
/U
FO1B
UB - 1.5
-
UB
LOW U
FO1A
/U
FO1B
0
-
1
Switching current per safety output
1
-
150
mA
Utilization category acc. to EN 60947-5-2
DC-13 24 V 150 mA
Caution: Outputs must be protected with a free-wheeling diode in case of inductive loads
Switching frequency
4)
0.5
Hz
Monitoring outputs OL, OI, OD
p-switching, short circuit-proof
Output voltage
0.8 x UB
-
UB
V DC
Max. load
-
-
50
mA
Solenoid
Solenoid operating voltage IMP (reverse polarity protected,
regulated, residual ripple < 5 %)
DC 24 V +10%/-15%
Solenoid current consumption I
IMP
400
mA
Power consumption
6
W
Duty cycle
100
%