6.3.
Switching states
The detailed switching states for your switch can be found in the system status table. All safety outputs, monitoring outputs
and display LEDs are described there.
Guard closed and locked
Guard closed and not locked
Guard open
Programming
State
D0, D1
D2, D3
Monitor diagnostics
Dual-channel
conditionally depen-
dent
Guard closed and locked
Code sequence
Green
Guard closed and not locked
Half-se-
quence
00
Yellow flashing
Invalid state
(guard open, guard locking active)
00
Half-se-
quence
Red flashing
(monitoring of the invalid state)
Guard open
00
00
Red
Address 0 or communication disrupted
–
Gray
Dual-channel
independent
Guard closed and locked
Code sequence
Green
Guard closed and not locked
Half-se-
quence
00
Red
Invalid state
(guard open, guard locking active)
00
Half-se-
quence
Red
Guard open
00
00
Red
Address 0 or communication disrupted
–
Gray
Dual-channel
dependent
Synchronization time
infinite
∞
Guard closed and locked
Code sequence
Green if guard was previously open
or yellow flashing after startup if only the guard locking
was open.
Guard closed and not locked
Half-se-
quence
00
Yellow flashing if guard was previously closed.
Red if guard was previously open.
Invalid state
(guard open, guard locking active)
00
Half-se-
quence
Yellow flashing if guard was previously closed.
Red if guard was previously open.
Guard open
00
00
Red
Address 0 or communication disrupted
–
Gray