![EUCHNER 106300 Operating Instructions Manual Download Page 13](http://html.mh-extra.com/html/euchner/106300/106300_operating-instructions-manual_2434808013.webp)
13
106595-09-06/20 (Translation of the original operating instructions)
Operating Instructions
Non-Contact Safety Switch CES-AH-C03-AH-SM
EN
8.9. Connector assignment
1
2
3
4
5
9
6
7
8
View of connection side
Figure 1:
Connector assignment of safety switch CES-AH-C03-AH-SM
Pin
Designation
Description
1
NC
Not used *
2
Start
Start input
3
LA
Safety output, channel 1
4
+LA
Input for channel 1
5
+LB
Input for channel 2
6
LB
Safety output, channel 2
7
UB
Power supply, DC 24 V
8
0 V
Ground, DC 0 V
9
NC
Not used *
* The unused connection pins are not allowed to be connected by the user!