background image

Figure 4. USRP-2900 Module Back Panel Connectors

+15 dBm MAX

PPS

5V MAX

USB

PWR

IN

6V

 1 A MAX

REF IN

Connector Use

REF IN

Input terminal for an external reference signal for the local oscillator (LO) on the

device. REF IN is a female SMA connector with an impedance of 50 Ω, and it is a single-

ended reference input. REF IN accepts a 10 MHz signal with a minimum input power of

0 dBm (0.632 V

pk-pk

) and a maximum input power of 15 dBm (3.56 V

pk-pk

) for a square

wave or sine wave.

USB

Input that accepts a standard USB cable. A suitable USB cable is included in the

hardware kit.

PPS IN

Input terminal for pulse per second (PPS) timing reference. PPS IN is a female SMA

connector with an impedance of 50 Ω, and it is a single-ended input channel. PPS IN

accepts 0 V to 3.3 V TTL and 0 V to 5 V TTL signals.

PWR

Input that accepts a 6 V, 3 A external DC power connector.

USRP-2901 Connectors and LEDs

Figure 5. USRP-2901 Front Panel

NI USRP-2901

70 MHz–6 GHz

ESD

SENSITIVE

RF 0

TX1 RX1

RX2

RF 1

TX1 RX1

RX2

Designed by Ettus Research

TX OUTPUT MAX +20 dBm, RX INPUT MAX –15 dBm, ALL RF PORTS 50

Ω

Connector

Use

RF 0 TX1 RX1 Input and output terminal for the RF signal. TX1 RX1 is an SMA (f) connector with an

impedance of 50 Ω and is a single-ended input or output channel.

RX2

Input terminal for the RF signal. RX2 is an SMA (f) connector with an impedance of

50 Ω and is a single-ended input channel.

RF 1 RX2

Input terminal for the RF signal. RX2 is an SMA (f) connector with an impedance of

50 Ω and is a single-ended input channel.

© National Instruments

15

USRP-2900/2901 Getting Started

Summary of Contents for USRP-2900

Page 1: ...USRP 2900 2901 Getting Started 2022 07 11 ...

Page 2: ...B Connection 8 Changing the Device ID 9 Programming the USRP 2900 2901 11 NI USRP Instrument Driver 11 NI USRP Examples 11 Verifying the Device Connection Optional 11 Troubleshooting 12 Why Doesn t the USRP Device Appear in MAX 12 Why Doesn t the USRP Device Appear in the NI USRP Configuration Utility 12 Front Panels and Connectors 13 Direct Connections to the USRP 2900 2901 13 USRP 2900 Connector...

Page 3: ...product is connected to a peripheral device or test object or if the product is used in residential or commercial areas To minimize interference with radio and television reception and prevent unacceptable performance degradation install and use this product in strict accordance with the instructions in the product documentation Furthermore any changes or modifications to the product not expressly...

Page 4: ...a metal part of the computer chassis 2 Remove the device from the package and inspect the device for loose components or any other sign of damage Caution Never touch the exposed pins of connectors Note Do not install a device if it appears damaged in any way 3 Unpack any other items and documentation from the kit Store the device in the antistatic package when the device is not in use ni com 4 USR...

Page 5: ...RP 2900 2901 Getting Started Guide This Document Note The driver software media installs the NI USRP driver software and electronic documentation including the NI USRP Help the NI USRP Readme and device specifications After installation you can access USRP 2900 2901 documentation at Start All Programs National Instruments NI USRP Documentation Other Required Items In addition to the kit contents y...

Page 6: ...e environment you are using the USRP 2900 2901 in meets the following specifications Ambient temperature range 0 C to 55 C Operating temperature 23 C 5 C Operating humidity 10 to 90 relative humidity noncondensing Pollution Degree 2 Maximum altitude 2 000 m Indoor use only Caution Do not operate the USRP 2900 2901 in a manner not specified in this document Product misuse can result in a hazard You...

Page 7: ...g USRP 2900 2901 Devices Install LabVIEW Communications System Design Software and NI USRP before you install the hardware Note The USRP 2900 2901 device connects to a host computer using a standard USB connector and USB cable 1 Power on the computer 2 Attach the antenna or cable to the front panel terminals of the USRP 2900 2901 device as needed for your application 3 Use the USB cable to connect...

Page 8: ...nal Reference Clock distribution system such as the CDA 2990 Clock Distribution Device However USB performance varies when multiple devices stream through the same controller Consider using a USRP RIO device if you need to build a high channel count system Confirming USB Connection 1 Select Start All Programs National Instruments NI USRP NI USRP Configuration Utility to open the NI USRP Configurat...

Page 9: ...SRP Configuration Utility to open the NI USRP Configuration Utility 3 Select the Devices tab of the utility Your device should appear in the list on the left side of the tab 4 In the list select the device for which you want to change the device ID If you have multiple devices verify that you selected the correct device The device ID of the selected device displays in the Selected Device ID textbo...

Page 10: ...le the device and click Find Devices in the utility to update the list of devices Configuring Multiple Devices with USB You can connect multiple devices in the following ways Multiple USB 2 0 or 3 0 interfaces One device for each interface Single USB 2 0 or 3 0 interface Multiple devices connected to a USB 2 0 or 3 0 hub Tip Sharing a single USB 2 0 or 3 0 controller interface on your host compute...

Page 11: ...emonstrate some of the functionality of the USRP 2900 2901 You can use these examples separately or integrate them into your systems NI USRP includes examples for getting started and other SDR functionality You can access the NI USRP examples from the following locations In LabVIEW Communications System Design Software at Learning Examples Hardware Input and Output From the Start menu at Start All...

Page 12: ...vice and connect the other end of the SMA m to SMA m cable to the RX 1 TX 1 port 3 On the host computer open the niUSRP EX Tx Continuous Async example VI and run it If the device is transmitting signals the IQ graph displays I and Q waveforms 4 Open the niUSRP EX Rx Continuous Async example VI and run it If the device is receiving signals the IQ graph displays I and Q waveforms Troubleshooting If ...

Page 13: ...s sensitive to ESD and transients Ensure you take the following precautions when making direct connections to the USRP 2900 2901 to avoid damaging the device Caution Apply external signals only while the USRP 2900 2901 is powered on Applying external signals while the device is powered off may cause damage Ensure you are properly grounded when manipulating cables or antennas connected to the USRP ...

Page 14: ... Front Panel Icon Definitions Connector Use RX2 Input terminal for the RF signal RX2 is an SMA f connector with an impedance of 50 Ω and is a single ended input channel TX1 RX1 Input and output terminal for the RF signal TX1 RX1 is an SMA f connector with an impedance of 50 Ω and is a single ended input or output channel Table 4 USRP 2900 Module Front Panel Connectors LED Description Color Indicat...

Page 15: ...dance of 50 Ω and it is a single ended input channel PPS IN accepts 0 V to 3 3 V TTL and 0 V to 5 V TTL signals PWR Input that accepts a 6 V 3 A external DC power connector USRP 2901 Connectors and LEDs Figure 5 USRP 2901 Front Panel NI USRP 2901 70 MHz 6 GHz ESD SENSITIVE RF 0 TX1 RX1 RX2 RF 1 TX1 RX1 RX2 Designed by Ettus Research TX OUTPUT MAX 20 dBm RX INPUT MAX 15 dBm ALL RF PORTS 50 Ω Connec...

Page 16: ... device Off The device is not active Green The device is receiving data TX1 RX1 Indicates the transmit status of the device Off The device is not active Green The device is receiving data Red The device is transmitting data Orange The device is switching between transmitting and receiving data Table 5 USRP 2901 Module LEDs Figure 6 USRP 2901 Module Back Panel Connectors 15 dBm MAX PPS 5V MAX USB P...

Page 17: ...you receive important information updates from NI A Declaration of Conformity DoC is our claim of compliance with the Council of the European Communities using the manufacturer s declaration of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety You can obtain the DoC for your product by visiting ni com certification If your product supports ...

Reviews: