background image

          

SM1-SS Microphone Instructions

 

 
The SM1-SS is a stainless steel, high quality, 12VDC powered, flush mount, omni-directional, 
pre-amplified microphone with a for use with DRVs, I/P cameras, etc. Note- the audio output of 
the SM1 is jumper selectable “line level” (0db) or “microphone level” (-30db). 
 

SM1-SS Microphone Placement. 

Locate the SM1-SS Microphone near the area of interest in the room to be monitored. If the entire 
room is to be monitored, locate the SM1-SS in the middle of the room. Do not mount the 
microphone near air conditioning vents, light fixtures or electrical equipment. The SM1-SS should 
be placed at least five feet away from the subject(s) to be monitored. The SM1-SS is still useable 
in the range of 15-25 feet but is dependent on the level of background noise in the area. 
Experimentation in the environment will determine what distances work best. 
 

Cable Run 

Run a 22 gauge, stranded, two conductor shielded cable between the SM1-SS microphone and 
the monitoring device. Keep the cable run distance under 1,000 feet and away from AC power 
sources, light fixtures and electrical equipment. Connect power to the + terminal, the audio signal 
to the “audio” terminal and ground to the – terminal.  The Ground of the power and audio signal 
must share a common ground for proper operation. 

See Figure 1 for connection diagram. 

 
Mounting 

The SM1-SS can be surface or flush mounted on ceilings or walls. For flush mounting, cut a 2 ¼” 
by 2 ¾

 

“ hole in the wall or ceiling tile to allow room for the circuit board and mount the SM1-SS to 

the surface with screws. A single gang electrical box can be used for surface mounting or 
consider using an SM1-SS-LE in place of the SM1-SS. 
 

Adjusting the SM1-SS Gain 

The SM1-SS output level is set by selecting the desired volume range and adjusting the gain 
control. 

 

The “Volume Range” jumper should be set to the “LO” position when using the SM1-SS with I/P 
cameras that utilize “microphone inputs” also know as “Mic. Level”  inputs. This sets the 
maximum gain of the SM1-SS’s pre-amp to x14. The jumper should be placed in the “HI” position 
when using I/P cameras with “Line level” inputs of DVRs and I/P cameras. This sets the 
maximum gain of the SM1-SS’s pre-amp to x196. 
 
The SM1-SS is shipped with the gain set at midrange. If the sound at the “head end” is distorted, 
rotate the control towards the – mark (counter-clockwise). If the volume at the “head end” is too 
low, rotate the control towards the + mark (clockwise).   
 

Setting the SM1-SS Hi-Cut/Lo-Cut Jumpers 

The normal frequency response of the SM1-SS microphone is 500-13Khz.  When both jumpered 
“in”, The “HI Cut” and “Lo Cut” filters set the SM1-SS’s frequency response to 900-6Khz . 
Enabling one or both of the filters is useful when background noise needs to be further reduced 
and intelligibility of speech emphasized. We recommend experimenting with the jumper settings 
to achieve the best acoustic result for your application. 
 