Safety notes

•  This manual consists of important information on the instruction and safety of the Ozone Cleaning System. 

Read this manual carefully before installing, commissioning or performing maintenance or repair work on 

the system.

•  Always wear appropriate protective clothing when handling the equipment.
•  The Ozone Cleaning System is intended only for the treatment of exhaust air as described in these instructions.
•  The Ozone Cleaning System uses high voltage to create an electric charge that generates ozone (O

3

). Ozone 

significantly reduces odor, grease, mold and bacteria. ETS NORD AS disclaims any liability in the case 

that the product is not used in accordance with the manufacturer’s instructions contained in this manual. 

 

Installation flowchart

For ease of installation and service, it is suggested the installing contractor have the following tools on hand:

•  Narrow 2mm flat-head screwdriver
•  #1 Phillips screwdriver 
•  T4 screwdriver
•  Small flashlight  
•  Electrical fish tape
•  Silicone and silicone gun

Install ozone 

module to 

the supply air 

chamber

Mount Control 

Panel

Perform electrical 

installation of the 

system

Connect supply 

mains for control 

panel and ozone 

modules

Connect data 

wiring for all 

ozone modules

Check the product 

shipment

Set unique device 

addresses and 

apply sequential 

number stickers

Connect two 

pressure 

measurement 

tubes

Summary of Contents for NORDcanopy OZ 3.1

Page 1: ...NORDcanopy OZ 3 1 Ozone Cleaning System Installation Guide...

Page 2: ...the device addresses 5 4 Installation 6 4 1 General information 6 4 2 Connect the pressure measurement hoses 7 4 3 Mount the Control Panel 8 5 Electrical Installation 9 5 1 Connect the main electrical...

Page 3: ...one O3 Ozone significantly reduces odor grease mold and bacteria ETS NORD AS disclaims any liability in the case that the product is not used in accordance with the manufacturer s instructions contain...

Page 4: ...ch kitchen The number of Ozone Modules is dependent on the design of the kitchen and the canopy as well as the equipment used for cooking This is decided when planning the kitchen 2 System overview Th...

Page 5: ...ontrol Panel and increasing by one for each sequential module The first connected Ozone Module should have the address 1 Example Ozone Module one Adress 1 Switch 1x 1 Switch 10x 0 Ozone Module thirtee...

Page 6: ...facturer s drawings The ozone duct must be made of acid resistant stainless steel AISI 316 Before starting the Ozone Module check visually that all ozone duct connections are airtight Always leave a m...

Page 7: ...module Feed the long hose through the 100mm ozone duct into the exhaust chamber While lifting the module into place securely attach one end of the hose to the hose located in the Ozone Module 100mm fl...

Page 8: ...it near any sources of moisture or heat The housing must be disassembled into three parts Remove the two fixing screws on the sides of the case Before mounting the backplate apply an even strip of wa...

Page 9: ...lied to the ozone system See the sample diagram below as one possible option to accomplish this function A maximum of 4 Ozone Modules and one alarm panel may be connected a single 10A C type slow circ...

Page 10: ...r the rear wall or the cable bushings in the bottom of the case Connect the 230V supply cable to the power supply terminals L N and PE as shown in the diagram Each Ozone Module has its own power cable...

Page 11: ...format That is similar terminals between devices are connected together there are no specific in or out data terminals on the various components Maximum limit for the number of Ozone Module connected...

Page 12: ...of any Ozone Module in the chain should share the same terminal screw in its respective connector In this way the three extra unused terminals just below on the connector block can be reserved for fu...

Page 13: ...ard as seen below LAN cable must be connected to a network switch or to the closest LAN socket Reassemble the housing in reverse order with the smaller LED display above the larger one Ensure the text...

Page 14: ...ction chamber of the canopy and that the bottom edges of all filters do not have any gaps Call service is lit is red This indicates a technical fault has been detected in the system Contact your ETS N...

Page 15: ...the initial commissioning of the device has been performed by an authorized partner of ETS NORD AS the equipment is serviced every 12 months after commissioning specified components eg ozone generatin...

Page 16: ...etsnord ee ETS NORD Finland Address Pakkasraitti 4 04360 Tuusula Finland Phone 358 401 842 842 info etsnord fi www etsnord fi ETS NORD Sweden Address J rsj gatan 7 69235 Kumla Sweden Phone 46 19 554...

Reviews: