OZ 3.0 Installation Guide
5.1 Connect the main electrical supply
Each ozone generator has its own power supply connection:
- A maximum of 4 ozone generators and one alarm panel may be connected a single 10A low-speed circuit
breaker.
- Please label the circuit breaker number used on each generator as would normally be done for external
appliances.
Control Panel power cables may be fed through either the rear wall or the cable bushings in the bottom of the
case. Connect the 230V supply cable to the power supply terminals L, N and PE, as shown in the diagram.
Each Ozone Module has its own power cable that can be found inside the packaging. Connect it to the Ozone
Module as seen in the picture below.
.
25W Power supply
230V supply
cable
N
L
PE
230V from mains
Power Supply
SUPPLY 230V
IEC C13