GENERATOR USE
! WARNING
·
To prevent electrical shock from faulty appliances, the generator
should be grounded.
Connect with a heavy wire between the generator ground
terminal and on external ground source.
·
Connections from standby power to a building’s electrical system
must be made by a qualified electrician and must comply with all
applicable laws and electrical codes. Improper connections can
make electrical current from the generator to back feed into the
utility lines. Suck back feed may electrocute utility company workers
or others who come into contact with the lines during a power
outage, and when utility power is restored the generator may
explode, burn, or cause fires in the building’s electrical system.
GROUND TERMINAL
EARTH MARK
①
AC applications
·
start the engine and make sure the output indicator light (green) is
on.
Make sure that the appliance to be used is switched off, and plug
in the appliance.
~