INSTALLATION
DOC_DEV_IPL_User Guide_C
Page 23
All models except IPL-X-100
Ground terminal
Symbol
Description
FASTON male lug 6.35 mm
Ground terminal
Symbol
Description
M4 screw terminal
All models except IPL-X-100
2 positions screw terminal: Supply voltage 1
Position 1 at back
–
Protected against reverse polarity
Position
Signal
Function
1
Power 1 +
12 - 48 VDC
2
Power 1 -
0V
All models except IPL-X-100
2 positions screw terminal: Supply voltage 2
Position 1 at back
–
Protected against reverse polarity
Position
Signal
Function
1
Power 1 +
12 - 48 VDC
2
Power 1 -
0V
IPL-X-100
2 positions screw terminal: Supply voltage
Protected against reverse polarity
Position
Signal
Function
1
Power 1 +
12 - 24 VDC
2
Power 1 -
0V
All models except IPL-X-100
4 positions screw terminal: Digital input and output
Position 1 at back
Position
Signal
Function
1
0V
Digital input 0V
2
In
Digital input
3
F +
Digital (max 50Vdc - 0,1A)
4
F -
Digital output -
Ethernet RJ45 connector
Position
Signal
Function
RJ45
1
Tx +
Emission po
2
Tx -
Emission polarity -
3
Rx +
Reception po
4
N.C
-
5
N.C
-
6
Rx -
Reception polarity -
7
N.C.
-
8
N.C.
-