MAINTENANCE
Page 92
User manual ref. 9017009-02
3G-GPRS-EDGE router IPL-G12
•
Serial gateway :
That page displays the current status of the serial gateways :
Type of the gateway(Modbus, RAW, Telnet …),
serial port set-up (data rate etc…),
number of characters received or sent,
Number of TCP frames or UDP datagrams received or sent,
Number of TCP connections enabled.
The View link displays a window which shows the hexadecimal received
and transmitted traffic< over each serial COM port.
•
Ping :
That screen enables to send a ping frame to an IP address.
•
IO control
That screen displays the status of the digital input and output and allows
to set ON or OFF the alarm digital output.
2 Saving the parameters to a file
Once a product has been configured, the parameters file can be stored
and restored when necessary.
To save the parameters file,
Select the “System” menu and then “Save restore”,
Click the ”Save” button
Select the location to store the file and give a name to the file.
The file suffix is “.bin”
To restore a parameters file
Select the “System” menu and then “Save restore”,
Click the “browse” button and select the parameters file,
Click the “Load” button and confirm to restart the product.
Attention :
A parameters file can only be restored towards a product
having the same firmware version. It is why, we advise to assign a name
to a parameter file including the product name and the software version
like for instance “myrouterfile_iplg12_V241.bin”.