OVERVIEW
Page 8
User manual ref. 9017009-02
3G-GPRS-EDGE router IPL-G12
2 Technical data
General characteristics
Dimensions
128 x 38 x 107 mm (h, l, p)
Electrical safety
EN 60950- UL 1950
CEM
ESD : EN61000-4-2 : Discharge 6 KV
RF field : EN61000-4-3 : 10V/m < 2 GHz
Fast transient : EN61000-4-4
Surge voltage : EN61000-4-5 : 4KV line / earth
RoHS 2002/95/CE
(RoHS)
Supply voltage
9 to 30 VDC - 170 mA at 24 VDC
Operating T°
-20°C / + 60°C
Humidity 5 - 95 %
3G & GPRS-EDGE & GSM data
RF Frequencies
850/900/1800/1900 / 2100 MHz
(see detailed table below)
RF power
EGSM850 EGSM900 : class 4 (2 W)
GSM1800 GSM1900 : class 1 ((1 W)
RF connector
FME
UMTS *
HSDPA
384 kbps
downlink
/ 384 kbps
uplink
EDGE-GPRS **
Max data rate : 85,6 Kb/s downlink & 21,4 Kb/s uplink
Multislot class 10
GPRS **
Multislot class 12
GSM data ***
9600 b/s
* IPL-G12B-3G only ** IPL-G12B-3G and IPL-G12B
*** IPL-G12B only
UMTS Frequency range (3G)
Min
Max
UMTS 850 Band V
824 MHz
849 MHz
UMTS 1900 Band II
1850 MHz
1910 MHz
Uplink (UE to Node B)
UMTS 2100 Band I
1920 MHz
1980 MHz
UMTS 850 Band V
869 MHz
894 MHz
UMTS 1900 Band II
1930 MHz
1990 MHz
Downlink (Node B to UE)
UMTS 2100 Band I
2110 MHz
2170 MHz