INSTALLATION
Page 20
User manual ref. 9017009-02
3G-GPRS-EDGE router IPL-G12
1.3
DIP-switches
DIP switches
SW 1 SW 2
Management
OFF
OFF
The current IP@ of the product is the stored IP @
ON
OFF
The active IP@ of the product is the factory IP@ : 192.168.0.128
No login and password are required to access to the html server
OFF
ON
The active IP@ is provided by the BOOTP or DHCP server.
ON
ON
Reserved
SW 3, SW 4
Not used
Push-button : It enables to restore the factory profile.
To restore the factory profile, switch the power on while pressing the
push-button until the RUN light turns green.
Attention
: Once the factory profile has been restored, the stored
configuration is lost.
2 Ventilation
To avoid overheating when the ambient temperature is high, leave a 1 cm
(0.5 inch) space on each side of the product.
3 Supply voltage
The supply voltage must be strictly lower than 30 VDC and higher than 9
VDC. The consumption is 170 mA at 24 VDC.
Careful : The supply voltage module must be able to provide current
peaks absorbed by the GSM RF transmitter.
4 Ethernet interface
The Ethernet interface is a 10 Mb/s interface.
To connect a PC directly to the IPL, use the cross wired red cable
provided with the product.