HTML SET UP & DIAGNOSTIC
Page 36
User’s guide ref 9014709-02
XSLAN SHDSL switch
Setting up The XSLAN Nr 2
•
Select the Ethernet & switching” menu and then the “SHDSL port” menu.
•
Select the NTU checkbox for port 1 and 2.
•
Select the “Signal power” value “Auto” for port 1 and port 2.
•
Select the “SHDSL ports aggregation” checkbox.
•
Save and click the reboot button.
12.2
Testing the SHDSL connection and adjusting the data rate
Proceed as follows for each of the two SHDSL connections.
•
Connect two XSLAN to the two twisted pairs, check the line led of
each SHDSL interface (the lower led of each SHDSL connector) blinks
during the connection (45 seconds) and then lights on permanently.
Remark : T
he LINE leds glitters slightly with the shdsl traffic.
•
If the led blinks endlessly, it means the connection cannot be
established; select a lower data rate.
•
Once the connection is established, select the “Diagnostic” menu, and
then the “Network status” menu and then the “Statistics” menu.
Check the “SNR margin” is greater than 6. Otherwise decrease the data
rate.
•
Select the “Diagnostic” menu, and then the “Logs” menu.
•
Check the XSLAN remains permanently connected. Disconnections
must be very rare. If disconnections are frequent, check the line itself
and / or decrease the data rate.