
HTML SET UP & DIAGNOSTIC
Page 34
User’s guide ref 9014709-02
XSLAN SHDSL switch
11.2
Testing the SHDSL connection and adjusting the data rate
•
Connect two XSLANs to a line, check the line led (the lower led of the
SHDSL connector) blinks during the connection (about 45 seconds) and
then lights on.
•
If the led blinks endlessly, it means the connection cannot be
established; select a lower data rate.
•
Once the connection is established, select the “Diagnostic” menu, and
then the “Network status” menu and then the “Statistics” menu.
Check the “SNR margin” is greater than 6. Otherwise decrease the data
rate.
•
Select the “Diagnostic” menu, and then the “Log” menu.
Check the XSLAN remains permanently connected. Disconnections
must be very rare. If disconnections are frequent, check the line itself
and / or decrease the data rate.
Summary of Contents for 1220
Page 10: ......
Page 60: ......
Page 63: ...APPENDIX 2 HTML server XSLAN SHDSL switch User s guide ref 9014709 02 Page 63 ...