DIP-SWITCHES SET UP
3
Two twisted pairs SHDSL line set up (XSLAN-2400, 2220, 2230)
When two XSLANs SHDSL switches are connected through a 2 twisted
pairs line,
up to 4,6 Mb/s instead of 2,3 Mb/s can be provided;
The data flow is automatically shared over the two pairs;
both ports of the XSLAN Nr 1 have to be set as a LTU (calling party)
and both ports of the other one have to be configured as an “NTU”.
(called party).
The DIP switches allow to set up the port 1. Once the port 1 has been set
up with the DIP switches, the port 2 is then automatically set up by the
product itself.
•
XSLAN Nr 1 set up
SW1 & SW2
Set up DIP switches SW1 an SW2 ON to enable DIP switches operations.
SW3, SW4, SW5
Set the XSLAN Nr 1 as a LTU and select the data rate according to the
distance and the cable quality (see appendix 1).
•
XSLAN Nr 2 set up
SW1 & SW2
Set up DIP switches SW1 an SW2 ON to enable DIP switches operations.
SW3, SW4, SW5
Set SW3, SW4, SW5 OFF to set up the XSLAN Nr 2 as a NTU.
XSLAN SHDSL switch
User’s guide ref 9014709-02
Page 23