SETUP
Page 18
DOC_DEV_XS_Setup guide_C
3.3
Step 2 : SHDSL test and set up adjustment
•
Connect the XS to the twisted pairs. The wires of the same twisted pair can be reversed.
•
Power on the XS.
•
The connection takes about 45 s to establish with the « standard » profile and may takes a longer time with
other profiles.
•
The SHDSLx LEDs attached to each port displays the state of the connection as described in the table
below.
State of the connection
SHDSL LED
The other XSLAN was not detected
(for example when the line is not connected)
Blinking 0,1 s ON / 2 s OFF
Data rate negotiation
Blinking 0,3 s ON / 0,3 s OFF
Connected
Steady on
Traffic on the link
Flashing
•
Once connected, choose
Diagnostics > Network status > Interfaces
in the menu to check the SHDSL link
quality.
Summary of Contents for XLAN+ Series