HUMIDITY SENSOR ASSEMBLY REPLACEMENT PROCEDURE | PART NO.
24104
REV
B.0
MODEL ADH
ADH NETCOM AUTOMATIC AIR DEHYDRATOR
HUMIDITY SENSOR ASSEMBLY REPLACEMENT PROCEDURE
Replacement Kit Part Number 2409
2
Document Part Number 24104
Page 1: ...NSOR ASSEMBLY REPLACEMENT PROCEDURE PART NO 24104 REV B 0 MODEL ADH ADH NETCOM AUTOMATIC AIR DEHYDRATOR HUMIDITY SENSOR ASSEMBLY REPLACEMENT PROCEDURE Replacement Kit Part Number 24092 Document Part N...
Page 2: ...imum operating temperature of 130 F 55 C will not be compromised by other components in the rack Ensure reliable earthing of the ADH NETCOM ADH NETCOM HUMIDITY SENSOR ASSEMBLY REPLACEMENT PROCEDURE Th...
Page 3: ...raps securing the humidity sensor assembly to its tie wrap mounts then move the sensor out of the way to gain access to the electrical connector Using a small tool press in on either orange release ta...
Page 4: ...dity sensor onto the two tie wrap mounts from which the original assembly was removed Before securing the new humidity sensor in place rotate the sensor on the two mounts so that the two air hoses rea...