ETI Solid State Lighting AHB-SEL-22000LM-8-50K-MV-LVD Use And Care Manual Download Page 1

Model # 502501620

Part # AHB-SEL-22000LM-8-50K-MV-LVD

Certification # 502501620

USE AND CARE GUIDE

ADJUSTABLE BEAM HIGH BAY

INSTALLATION 

Select a suitable location that can support the weight of the 

fixture. Determine the method for mounting the fixture before 

LIGHT DISTRIBUTION 

PACKAGE CONTENTS

Part Description 

Quantity 

A

Fixture Body

1

NOTE

Keep your receipt and these instructions for proof of purchase.

WARNING

Shut off the power at the circuit breaker or fuse panel before removing the old fixture, ballast, or fluorescent tubes.

               If you are unfamiliar with electrical installations, we recommend you contact a qualified electrician to do the installation.

A

HARDWARE INCLUDED

Part Description 

Quantity 

AA  Mounting Chain

1

BB

Lifting Hook

1

CC

Wire Connector

5

DD

Short Screw

1

EE

Long Screw

1

AA

BB

CC

DD

EE

drilling, based on the type of ceiling.

 NOTE

The fixture’s net weight is 9.15lbs (without 

accessories), The minimum load-bearing capacity required for 

the ceiling hook is 38.5lbs (4 times the high bay weight)

A

BB

AA

AA

BB

EE

Hex key

AA

“S” shape

“S” shape

Hook

 

(not included)

BB

DD

DD

1.  Screw the hook (BB) into the threaded hold clockwise. 

Tighten screw (DD) with screwdriver to secure hook.

2.

 

Take out mounting chain (AA) and close “S” chain ring using pliers.

3.  Hang the HighBay with lifting hook (BB) on the chain (AA), Screw (EE) to the lifting hook (BB) as show in the above picture 

using the hex key.

4.  Unscrew the two screws on the top of the fixture (A) using a Phillips head screwdriver counter clockwise to open the lid. 

Remove the two plastic plugs and feed the conduit (not included) and all the electrical connection wires through the 1/2” holes.

5.  Connect the hot and neutral (black and white) wires from the electrical box to the same color wires from the fixture body (A). Connect 

the ground wire from the electrical box to the green wire from the fixture body (A). If a 0-10v dimming circuit is available, connect the 
purple and gray wires from the electrical box to the same color wires from the fixture body (A). If dimming is not desired, wrap the 
ends of the purple and gray wires with electrical tape to cover the wires. Cover the wire connections using the wire connectors (CC).
Wrap the wire connectors (CC) with electrical tape for a secure connection. 

6.  Position the wires inside the fixture body (A) and reattach the lid to the fixture body (A).

 NOTE: 

Apply silicone sealant (not included) to the joint between the wire pipe and the fixture so that the fixture can be 

completely waterproof and dustproof.

0

30

60

90

120

150

-/+180

-150

-120

-90

-60

-30

UNIT:cd

C0/180,117.6

UNIT:cd

C30/210,114.6

UNIT:cd

C60/240,114.5

UNIT:cd

C90/270,117.6

AVERAGE BEAM ANGLE(50%):116.1 DEG

0

1800

3600

5400

7200

9000

Problem

Possible Cause

Solution

The fixture will not light.

The power is off.

Ensure the power supply is on.

The circuit breaker is off.

Ensure the circuit breaker is in the on position.

There is a bad connection.

Check to ensure proper wire connections are made. Contact a 

qualified electrician.

There is a defective switch.

Contact a qualified electrician.

The fuse blows or the 

circuit breaker trips when 

the light is turned on.

The wires are crossed or the 

power wire is grounding out.

Check the wire connections. Contact a qualified electrician or call 

customer service 1-855-384-7754.

CARE AND CLEANING

CAUTION: 

Before attempting to clean the tube and luminaire/light fixture, disconnect the power to the fixture by turning 

the breaker off or removing the fuse from the fuse box. Clean with a soft, dry cloth. Do not use cleaners with chemicals, 
solvents, or harsh abrasives. Do not use liquid cleaner on the LEDs, LED driver, or wiring.

TROUBLESHOOTING

Minor problems often can be fixed without the help of an electrician. 

WARNING:

 Before doing any work on the fixture, disconnect power to the light fixture.

WARNING: 

Carefully read and understand the information given in this manual before beginning the assembly and 

installation. Failure to do so could lead to electric shock, fire, or other injuries which could be hazardous or even fatal.  

 

 

To reduce 

the possibility of serious injury, always take the proper precautions and unplug the fixture before moving or cleaning.

NOTICE: 

Added weight of the device may cause instability of a free-standing portable luminaire.

NOTICE: 

This device is not intended for use with emergency exits or emergency lighting, electronic timers, or photocells.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 

installation.  This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance 

with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference 

will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, 

which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one 

and the receiver, connect the equipment into an outlet on a circuit different from that to which the receiver is connected, and 

consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party 

responsible for compliance could void the user’s authority to operate the equipment.

See website for Warranty, Troubleshooting or Care and Cleaning details at www.ETiSSL.com.

Questions, problems, missing parts? Call ETiSSL Customer Service 8 a.m. - 5 p.m., CST, Monday - Friday

1-855-ETI-SSLI (1-855-384-7754) www.ETiSSL.com

Plastic plug

A

Lid screw

Silicone 

sealant

Purple (+) Gray (-)
Black (B)

White (W)

Green (E)

CC

Conduit

(not included)

GUIDE D’UTILISATION ET D’ENTRETIEN

INSTALLATION 

Choisissez un endroit approprié pouvant supporter le poids du 
luminaire. Établissez la méthode de montage du luminaire en 
fonction du type de plafond, avant de percer un trou.

CONTENU DE L’EMBALLAGE

Pièce Désignation  

Quantité 

A

Boiitier du luminaire

1

REMARQUE 

Gardez votre facture ainsi que ces instructions comme preuves d’achat.

A

MATÉRIAUX INCLUS

Pièce Désignation  

Quantité 

AA  Chaîne de fixation

1

BB

Crochet de suspensioj

1

CC

Serre-fils

5

DD

Vis courte

1

EE

Vis longue

1

AA

BB

CC

DD

EE

 NOTE

              Le poids net du luminaire (sans accessoire) est de 
9.15 lb. La capacité de charge minimale requise pour le 
crochet de plafond est de 38.5 lb (4 fois le poids du luminaire).

A

BB

AA

AA

“S” Forme

“S” Forme

Crochet

 

(non inclus)

BB

DD

DD

1.  Vissez le crochet (BB) dans le trou fileté, dans le sens horaire. 

Serrez la vis (DD) à l'aide d'un tournevis pour fixer le crochet.

2. Retirez la chaîne de suspension (AA) et fermez le maillon en S à l'aide de pinces.

3.  Suspendez le luminaire par son crochet de suspension (BB) sur la chaîne (AA) puis posez la vis (EE) sur le crochet de 

suspension (BB) comme illustré, à l'aide de la clé hexagonale.

4.  Dévissez les deux vis sur le dessus du luminaire (A) à l'aide d'un tournevis à pointe Phillips en les tournant dans le sens antihoraire 

pour ouvrir le couvercle. Enlevez les deux bouchons de plastique et passez la conduite (non incluse) et tous les fils électriques à 
travers les orifices de 1/2 po.

5.

 

Connectez les fils de tension et neutre (noir et blanc) de la boîte électrique aux fils de la même couleur du boîtier du luminaire (A). 

Connectez le fil de terre de la boîte électrique au fil de terre du boîtier du luminaire (A). Si vous utilisez un circuit gradateur 0-10 V, 

connectez les fils violet et gris de la boîte électrique aux fils de la même couleur du boîtier du luminaire A). Si vous n'utilisez pas de 

gradateur, enveloppez le bout des fils violet et gris avec un rubant isolant. Couvrez les connexions à l'aide de serre-fils (CC) puis 

enveloppez les serre-fils (CC) avcec un ruban isolant pour consolider les connexions.

6.

 

Réinsérez les fils dans le boîtier du luminaire (A) puis remettez le coucerclke sur le boîtier du luminaire (A).

 

NOTE: 

                  Appliquez un scellant de silicone (non inclus) sur le joint entre la conduite et le boîtier du luminaire 
afin que ce dernier soit complètement étanche à l'eau et à la poussière. 

AA

BB

EE

Clé hexagonale

Prise en plastique

A

Vis du couvercle

scellant 
de silicone

Violet (+)

Gris (-)

Nior (B)

Blanc (W)

Vert (E)

CC

Conduit

(non inclus)

NOTICE: 

LUMINAIRE À FAISCEAU AJUSTABLE POUR HAUT PLAFOND

AVERTISSEMENT: 

Coupez le courant au panneau de disjoncteurs ou de fusibles avant d’enlever le vieux luminaire, le ballast ou les 

tubes fluorescents. Si vous n’êtes pas familiers avec les installations électriques, nous vous recommandons de faire appel à un 

électricien qualifié pour l’installation.

N° modèle  502501620

N° de pièce AHB-SEL-22000LM-8-50K-MV-LVD

N° de certification 502501620

Reviews: